SAN ANTONIO, TX —
OSHA Inspection: ARTCHITECTURAL.COM 2 LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of ARTCHITECTURAL.COM 2 LLC in 1350 E. SOUTHCROSS, SAN ANTONIO, TX 78223 (NAICS 337212). OSHA activity number 341683563.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARTCHITECTURAL.COM 2 LLC
- Site address
- 1350 E. SOUTHCROSS
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78223
- Mailing
- 502 RIVERSIDE DR., SAN ANTONIO, TX 78223
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337212
- Employees
- 6
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.101 B
- Issued
- Oct 11, 2016
- Abate by
- Oct 24, 2016
- Penalty
- Initial $2,138 · Current $214 Reduced
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: a) Iron Work Shop: On or about August 9, 2016, employee(s) in the metal shop were exposed to struck-by and high pressure system hazards from compressed gas cylinders that contained gases such as, but not limited to, Argon/Carbon Dioxide (75%/25%) and Helium, that were unsecured. b)Outdoor dock: On or about August 9, 2016, employee(s) on the outdoor dock of the iron shop were exposed to struck-by and high pressure system hazards from compressed gas cylinders that contained gases such as, but not limited to, Argon and Acetylene, that were unsecured.
Recent events (3)
- — F (S) $214.29
- — C (S) $2138
- — Z (S) $2138
1910.212 B
- Issued
- Oct 11, 2016
- Abate by
- Oct 24, 2016
- Penalty
- Initial $2,138 · Current $214 Reduced
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: Wood Work Shop: On or about August 9, 2016, employee(s) were exposed to struck-by and caught-in hazards from an unachored Delta Drill Press (Model FC 82A910) which was used for wood working processes.
Recent events (3)
- — F (S) $214.29
- — C (S) $2138
- — Z (S) $2138
1910.213 C01
- Issued
- Oct 11, 2016
- Abate by
- Oct 24, 2016
- Penalty
- Initial $3,741 · Current $214 Reduced
General-duty citation text
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: Wood Work Shop: On or about August 9, 2016, employee(s) were exposed to a caught-in hazard while operating a Powermatic 10 inch Tilting Arbor Saw (Model 66) which was not equipped with a blade guard for the portion of the saw above the table and above the material being cut.
Recent events (3)
- — F (S) $214.29
- — C (S) $3741
- — Z (S) $3741
1910.213 C02
- Issued
- Oct 11, 2016
- Abate by
- Oct 24, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator: Wood Work Shop: On or about August 9, 2016, employee(s) were exposed to a struck-by hazard while operating a Powermatic 10 inch Tilting Arbor Saw (Model 66) which was not equipped with a spreader.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.213 C03
- Issued
- Oct 11, 2016
- Abate by
- Oct 24, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: Wood Work Shop: On or about August 9, 2016, employee(s) were exposed to a struck-by hazard while operating a Powermatic 10 inch Tilting Arbor Saw which was not equipped with non kickback fingers or dogs.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.213 I01
- Issued
- Oct 11, 2016
- Abate by
- Oct 24, 2016
- Penalty
- Initial $2,672 · Current $214 Reduced
General-duty citation text
29 CFR 1910.213(i)(1): Non-working portion(s) of the blade of bandsaw(s) were not enclosed or guarded: Wood Work Shop: On or about August 9, 2016, and times prior thereto, employee(s) were exposed to caught-in hazards from the operation of a Northfield Foundry & Machine Co. 27 inch Bandsaw (SN: 502524-1) which was not equipped with a blade guard.
Recent events (3)
- — F (S) $214.29
- — C (S) $2672
- — Z (S) $2672
1910.219 E01 I
- Issued
- Oct 11, 2016
- Abate by
- Nov 3, 2016
- Penalty
- Initial $2,138 · Current $214 Reduced
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o): Wood Work Shop: On or about August 9, 2016, and times prior thereto, employee(s) were exposed to caught-in hazards from nip points on an unguarded motor belt on a Powermatic 10 inch Tilting Arbor Saw (Model 66) used for wood work.
Recent events (3)
- — F (S) $214.29
- — C (S) $2138
- — Z (S) $2138
1910.303 G01 I A
- Issued
- Oct 11, 2016
- Abate by
- Oct 24, 2016
- Penalty
- Initial $2,138 · Current $214 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(i)(A): Working space about electric equipment rated 600 volts, nominal, or less was not provided with the minimal depth in the direction of access to live parts as indicated in Table S-1: a) Wood Work Shop, near entrance : On or about August 9, 2016, employee(s) were exposed to a fire hazard in the area directly in front of an electrical panel, which was obstructed by the storage of heavy wood working equipment and combustible materials, such as wooden scraps. b) Wood Work Shop, center : On or about August 9, 2016, employee(s) were exposed to a fire hazard in the area directly in front of an electrical panel, which was obstructed by heavy wood working equipment and combustible materials, such as wooden scraps.
Recent events (3)
- — F (S) $214.29
- — C (S) $2138
- — Z (S) $2138
1910.305 D02
- Issued
- Oct 11, 2016
- Abate by
- Oct 24, 2016
- Penalty
- Initial $2,672 · Current $214 Reduced
General-duty citation text
29 CFR 1910.305(d)(2): Panel boards were not dead front: a) Iron Work Shop, Left side: On or about August 9, 2016, employee(s) were exposed to electrical hazards from an electrical panel (Square D Company) on a column near the entrance of the Iron Work Shop, which did not have a dead front. b) Metal Work Shop, Outdoor dock: On or about August 9, 2016, employee(s) were exposed to electrical hazards from an electrical panel (Square D Company) near the back wall of the dock which did not have a dead front and was not fully closed. c) Metal Work Shop, Outdoor dock: On or about August 9, 2016, employee(s) were exposed to electrical hazards from an electrical panel (Square D Company, CN: NQODQ2) near the back wall of the dock which did not have a dead front.
Recent events (3)
- — F (S) $214.29
- — C (S) $2672
- — Z (S) $2672
1910.305 B01
- Issued
- Oct 11, 2016
- Abate by
- Oct 28, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1): Unused openings in boxes, cabinets, or fittings were not effectively closed: Iron Work Shop, Left side: On or about August 9, 2016, employee(s) were exposed to electrical hazards from an electrical panel (Square D Company, Type NQOB) on a column near the entrance of the Iron Work Shop, which was not fully closed and was accessed to power iron working equipment.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 337212)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341683563.