UVALDE, TX —
OSHA Inspection: UVALDE PRODUCERS FEED MILL
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of UVALDE PRODUCERS FEED MILL in 1704 MILAM ST, UVALDE, TX 78802 (NAICS 424510). OSHA activity number 341686665.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UVALDE PRODUCERS FEED MILL
- Site address
- 1704 MILAM ST
- City
- UVALDE
- State
- TX
- ZIP
- 78802
- Mailing
- P.O. BOX 1770, UVALDE, TX 78802
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424510
- Employees
- 10
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.219 C02 I
- Issued
- Sep 30, 2016
- Abate by
- Oct 11, 2016
- Penalty
- Initial $2,138 · Current $850 Reduced
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: Mixing Department: On or about August 10, 2016, and at times prior to, employees were exposed to a machine guarding hazard while operating the primary mixer whose electric power transmission motor was coupled to the mixer via a horizontal shaft which was not enclosed.
Recent events (2)
- — I (S) $850
- — Z (S) $2138
1910.219 D01
- Issued
- Sep 30, 2016
- Abate by
- Oct 11, 2016
- Penalty
- Initial $2,138 · Current $850 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): Secondary mixing Department: On or about August 10, 2016, and at times prior to, employees were exposed to a caught-in hazard while operating the secondary feed mixer whose electric power transmission motor was coupled to the mixer via unguarded pulleys.
Recent events (2)
- — I (S) $850
- — Z (S) $2138
1910.219 E01 I
- Issued
- Sep 30, 2016
- Abate by
- Oct 11, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt: Secondary mixing Department: On or about August 10, 2016, and at times prior to, employees were exposed to a caught-in hazard while operating the secondary feed mixer whose electric power transmission motor was coupled to the mixer via unguarded belts.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 F03
- Issued
- Sep 30, 2016
- Abate by
- Oct 11, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: Secondary mixing Department: On or about August 10, 2016, and at times prior to, employees were exposed to a caught-in hazard while operating the secondary feed mixer whose electric power transmission motor was coupled to the mixer via unguarded chain and sprockets.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 C03 I
- Issued
- Sep 30, 2016
- Abate by
- Oct 11, 2016
- Penalty
- Initial $2,138 · Current $860 Reduced
General-duty citation text
29 CFR 1910.303(c)(3)(i): All splices and joints and the free ends of conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose a) Secondary mixing Department: On or about August 10, 2016, and at times prior to, employees were exposed to an electrical hazard while operating the Wind Machine, 16 inch portable fan, while the 120 Vac power cord was splice with a different cord and the cords were joined together and wrapped in black tape. b) Secondary mixing Department: On or about August 10, 2016, and at times prior to, employees were exposed to an electrical hazard while operating the Wind Machine, 16 inch portable fan, while the 120 Vac power cord was plugged into an extension cord which had a splice and the cords were joined together and wrapped in black tape.
Recent events (2)
- — I (S) $860
- — Z (S) $2138
More inspections at Uvalde Producers Feed Mill
View Uvalde Producers Feed Mill's full OSHA safety record →
More inspections in this industry (NAICS 424510)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341686665.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.