AVON, CT —
OSHA Inspection: ARDEN COURTS OF AVON CT, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ARDEN COURTS OF AVON CT, LLC in 100 FISHER DRIVE, AVON, CT 06001 (NAICS 623312). OSHA activity number 341686731.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARDEN COURTS OF AVON CT, LLC
- Site address
- 100 FISHER DRIVE
- City
- AVON
- State
- CT
- ZIP
- 06001
- Mailing
- 100 FISHER DRIVE, AVON, CT 06001
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 623312
- Employees
- 58
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.151 C
- Issued
- Sep 14, 2016
- Abate by
- Nov 1, 2016
- Penalty
- Initial $5,487 · Current $5,487
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: Kitchen: On, or about, August 10, 2016, an eyewash unit was not provided where employees used Eco Cutter Plus, a corrosive liquid, to clean the oven. The nearest eyewash unit was located in an employee breakroom that required keypad access to gain entry.
Recent events (1)
- — Z (S) $5487
1910.303 G02 I
- Issued
- Sep 14, 2016
- Abate by
- Nov 1, 2016
- Penalty
- Initial $6,859 · Current $6,859
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): Main Electrical Room: On, or about, August 10, 2016, employees were required to open the Securitron control panel to turn the door alarm system on and off. Exposed live terminals were located in the control box.
Recent events (1)
- — Z (S) $6859
1910.1030 D04 III A2III
- Issued
- Sep 14, 2016
- Penalty
- Initial $10,974 · Current $10,974
General-duty citation text
29 CFR 1910.1030(d)(4)(iii)(A)(2)(iii): During use, containers for contaminated sharps were not replaced routinely or were allowed to be overfilled: Country Lane Utility Room: On, or about, August 10, 2016, the sharps container mounted on the wall was overfilled. Razors were observed in the container above the manufacturers fill line and a razor was stuck in the inlet flap, preventing proper operation. Arden Courts of Avon was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA Inspection Number 314407206, Citation Number 1, Item Number 5 and was affirmed as a Final Order on October 9, 2012, with respect to a workplace located at Avon, Connecticut.
Recent events (1)
- — Z (R) $10974
1910.303 G01 II
- Issued
- Sep 14, 2016
- Abate by
- Nov 1, 2016
- Penalty
- Initial $548 · Current $548
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: On, or about, August 10, 2016, in the following locations, items were stored in front of electrical panels: A. Cottage House Mechanical Room. B. Garden Path Mechanical Room. C. Kitchen Hall. Arden Courts of Avon was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA Inspection Number 314407206, Citation Number 2, Item Number 3 and was affirmed as a Final Order on October 9, 2012, with respect to a workplace located at Avon, Connecticut. Arden Courts of Tampa was previously cited for a violation of an equivalent occupational safety and health standard [1910.303(g)(1)], which was contained in OSHA Inspection Number 316538131, Citation Number 1, Item Number 4 and was affirmed as a Final Order on June 28, 2012, with respect to a workplace located at Tampa, Florida.
Recent events (1)
- — Z (R) $548
1910.1030 C01 IV
- Issued
- Sep 14, 2016
- Abate by
- Nov 1, 2016
- Penalty
- Initial $274 · Current $274
General-duty citation text
29 CFR 1910.1030(c)(1)(iv): The Exposure Control Plan was not reviewed and updated at least annually: Facility: On, or about, August 10, 2016, the facility had not reviewed/updated the Exposure Control Plan since July 30, 2015. Arden Courts of Allentown was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA Inspection Number 891578, Citation Number 1, Item Number 1 and was affirmed as a Final Order on June 17, 2013, with respect to a workplace located at Allentown, Pennsylvania.
Recent events (1)
- — Z (R) $274
1910.1200 F06 II
- Issued
- Sep 14, 2016
- Abate by
- Nov 1, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical: Kitchen Hall Storage Closet: A container of OASIS All Purpose 133 concentrate was not provided with a label.
Recent events (1)
- — Z (O) $0
1910.1200 G08
- Issued
- Sep 14, 2016
- Abate by
- Nov 1, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they were in their work area(s): Facility: On, or about, August 10, 2016, the facility did not have Safety Data Sheets for the following cleaning products: OASIS MultiQuat 146, EcoLab Scout, EcoLab Cutter Plus and EcoShine.
Recent events (1)