AVON, CT —
OSHA Inspection: MODERN MECHANICAL SYSTEMS, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of MODERN MECHANICAL SYSTEMS, INC. in ARDEN COURTS OF AVON 100 FISHER DRIVE, AVON, CT 06001 (NAICS 238220). OSHA activity number 341686954.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MODERN MECHANICAL SYSTEMS, INC.
- Site address
- ARDEN COURTS OF AVON 100 FISHER DRIVE
- City
- AVON
- State
- CT
- ZIP
- 06001
- Mailing
- P.O. BOX 492, FARMINGTON, CT 06032
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 42
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.21 B02
- Issued
- Sep 7, 2016
- Abate by
- Oct 25, 2016
- Penalty
- Initial $5,300 · Current $3,710 Reduced
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: Jobsite located at Arden Courts of Avon, 100 Fisher Drive, Avon, Connecticut: On, or about, August 10, 2016, an employee who was using a multi-meter to troubleshoot an air conditioning unit had not been provided with Electrical Safety Related Work Practices training regarding safe work practices and what personal protective equipment was required to be worn when troubleshooting and/or when verifying that electrical equipment was de-energized.
Recent events (2)
- — I (S) $3710
- — Z (S) $5300
1926.95 A
- Issued
- Sep 7, 2016
- Abate by
- Oct 25, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition wherever it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact: Jobsite located at Arden Courts of Avon, 100 Fisher Drive, Avon, Connecticut: On, or about, August 10, 2016, an employee who was using a multi-meter to troubleshoot an air conditioning unit had not been provided with Electrical Safety Related Work Practices training regarding safe work practices and what personal protective equipment was required to be worn when troubleshooting and/or when verifying that electrical equipment was de-energized.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.417 B
- Issued
- Sep 7, 2016
- Abate by
- Oct 25, 2016
- Penalty
- Initial $4,240 · Current $2,968 Reduced
General-duty citation text
29 CFR 1926.417(b): Equipment or circuits that were de-energized did not have tags attached at all points where such equipment or circuits could be energized: Jobsite located at Arden Courts of Avon, 100 Fisher Drive, Avon, Connecticut: On, or about, August 10, 2016, a lock and tag had not been applied to a 60 amp breaker in order to isolate an air conditioning unit from its electrical source while it was being repaired.
Recent events (2)
- — I (S) $2968
- — Z (S) $4240
More inspections at Modern Mechanical Systems, INC.
View Modern Mechanical Systems, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238220)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341686954.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.