Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: POLYMAX THERMOPLASTIC ELASTOMERS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of POLYMAX THERMOPLASTIC ELASTOMERS, LLC in 3210 OAK GROVE AVENUE, WAUKEGAN, IL 60079 (NAICS 326199). OSHA activity number 341687317.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Polymax Thermoplastic Elastomers, LLC — free Get an email when a new federal OSHA severe-injury report for Polymax Thermoplastic Elastomers, LLC is published. One employer, no account, unsubscribe in one click.
Site address
3210 OAK GROVE AVENUE
City
WAUKEGAN
State
IL
ZIP
60079
Mailing
3210 OAK GROVE AVENUE, WAUKEGAN, IL 60079
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
18
Ownership type
A

2 citations on file for this inspection.

1910.178 L06

Other-than-serious 1 instance 3 exposed
Issued
Sep 7, 2016
Abate by
Oct 3, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l) with information including the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation:    a) Production Area- On August 9, 2016, the employer did not maintain certification records to certify that all employees were trained and evaluated prior to operating powered industrial vehicles.
Recent events (1)
  • — Z (O) $0

1910.334 A02 I

Other-than-serious 2 instances 5 exposed
Issued
Sep 7, 2016
Abate by
Oct 3, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):     a) Production Area/Dock Area- On or about August 9, 2016, the employer did not ensure that all flexible cords were inspected prior to use in order to identify hazards and ensure that they were free of defects and damage that may expose employees to injury. Damage to the outer jacket of flexible cords used to supply power to portable fans was found but the flexible cords were not removed from service.
Recent events (1)
  • — Z (O) $0

View Polymax Thermoplastic Elastomers, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341687317.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.