Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STACK BROS. MECHANICAL CONTRACTORS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STACK BROS. MECHANICAL CONTRACTORS, INC. in HILL AVENUE AND LAUREL STREET INTERSECTION, SUPERIOR, WI 54880 (NAICS 237310). OSHA activity number 341687556.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stack Bros. Mechanical Contractors, INC. — free Get an email when a new federal OSHA severe-injury report for Stack Bros. Mechanical Contractors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
HILL AVENUE AND LAUREL STREET INTERSECTION
City
SUPERIOR
State
WI
ZIP
54880
Mailing
3119 HILL AVENUE, SUPERIOR, WI 54880
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237310
Employees
45
Ownership type
A

6 citations on file for this inspection.

1926.21 B02

Serious Gravity 10 2 instances 2 exposed
Issued
Oct 3, 2016
Abate by
Oct 25, 2016
Penalty
Initial $8,730 · Current $4,800 Reduced
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:    (a) Road construction project located on Hill Avenue in Superior, WI; each equipment operator was not informed of the regulatory clearance requirements for operating equipment near energized overhead electrical transmission wires or what to do if they were to contact energized electrical wires.
Recent events (2)
  • — I (S) $4800
  • — Z (S) $8730

1926.600 A06 I

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 3, 2016
Abate by
Oct 18, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.600(a)(6)(i):  For lines rated 50kV or below, a minimum of 10 feet was not maintained between the energized line and the equipment:  (a) Road construction project located on Hill Avenue in Superior, WI; on or about July 5, 2016 and July 29, 2016, a long reach backhoe was operated less than 10 feet from energized overhead transmission lines and the backhoe boom contacted the energized overhead transmission lines.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 3, 2016
Abate by
Oct 13, 2016
Penalty
Initial $6,236 · Current $3,430 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:     (a) Road construction project located on Hill Avenue in Superior, WI; an adequate means of fall protection was not provided for unprotected edges of a concrete box culvert.
Recent events (2)
  • — I (S) $3430
  • — Z (S) $6236

1926.600 A06 IV

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 3, 2016
Abate by
Oct 18, 2016
Penalty
Initial $8,730 · Current $4,800 Reduced
29 CFR 1926.600(a)(6)(iv): A person was not designated to observe clearance of the equipment and give timely warning for all operations where it is difficult for the operator to maintain the desired clearance by visual means:    (a) Road construction project located on Hill Avenue in Superior, WI; on or about July 29, 2016, a designated spotter/ signal person was not provided and used to warn the backhoe operator against hazards presented by an energized overhead electric transmission line while they were operating a backhoe beneath the overhead transmission line.
Recent events (2)
  • — I (S) $4800
  • — Z (S) $8730

1926.602 A09 II

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 3, 2016
Abate by
Oct 18, 2016
Penalty
Initial $6,236 · Current $3,430 Reduced
29 CFR 1926.602(a)(9)(ii): Earthmoving or compacting equipment which had an obstructed view to the rear was operated in reverse gear while the equipment did not have in operation a reverse signal alarm distinguishable from the surrounding noise level:    (a) Road construction project located on Hill Avenue in Superior, WI; on or about July 29, 2016, the audible backup alarm on a skid-steer was not operational.
Recent events (2)
  • — I (S) $3430
  • — Z (S) $6236

1926.503 B01

Other-than-serious 1 instance 1 exposed
Issued
Oct 3, 2016
Abate by
Nov 1, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section (fall protection training) by preparing a written certification record which contained the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer:  (a) Road construction project located on Hill Avenue in Superior, WI; The employer did not provide written certification for fall protection training.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Stack Bros. Mechanical Contractors, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341687556.