Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WESTERN UTILITY CONTRACTORS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WESTERN UTILITY CONTRACTORS, INC. in ELIZABETH AVENUE & MADISON STREET, CHICAGO, IL 60636 (NAICS 237130). OSHA activity number 341689032.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Western Utility Contractors, INC. — free Get an email when a new federal OSHA severe-injury report for Western Utility Contractors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
ELIZABETH AVENUE & MADISON STREET
City
CHICAGO
State
IL
ZIP
60636
Mailing
2565 PALMER AVENUE, UNIVERSITY PARK, IL 60484
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237130
Employees
130
Ownership type
A

2 citations on file for this inspection.

1926.651 C02

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Oct 31, 2016
Abate by
Nov 8, 2016
Penalty
Initial $4,811 · Current $0 Reduced
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations  that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:  a) On or about Aug 10, 2016, at the jobsite list above - employees performing underground cable line installation were  not provided a safe means of access/ladder in a trench measuring six (6) feet two (2) inches to six (6) feet four (4) inches in depth; eleven (11) feet in length and eight (8) feet eight (8) inches in width.
Recent events (3)
  • — F (S) $0
  • — C (S) $4811
  • — Z (S) $4811

1926.652 A01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Oct 31, 2016
Abate by
Nov 8, 2016
Penalty
Initial $9,620 · Current $0 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective  system designed in accordance with 29 CFR 1926.652(c). The employer had not complied with the provisions of 29 CFR 1926.652(b)(1)(i):  a) On or about Aug 10, 2016, at the jobsite list above - employees performing underground cable line installation were in a trench measuring six (6) feet two (2) inches and six (6) feet four (4) inches in depth; eleven (11) feet length and eight (8) feet eight (8) inches in width that was not provided with cave in protection.
Recent events (3)
  • — F (S) $0
  • — C (S) $9620
  • — Z (S) $9620

View Western Utility Contractors, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341689032.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.