CHESTER, CT —
OSHA Inspection: SAMSARA FITNESS LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SAMSARA FITNESS LLC in 8 INSPIRATION LANE, CHESTER, CT 06412 (NAICS 339920). OSHA activity number 341690469.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SAMSARA FITNESS LLC
- Site address
- 8 INSPIRATION LANE
- City
- CHESTER
- State
- CT
- ZIP
- 06412
- Mailing
- 10 DENLAR DRIVE, CHESTER, CT 06412
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339920
- Employees
- 8
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.101 B
- Issued
- Oct 17, 2016
- Penalty
- Initial $1,159 · Current $811 Reduced
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: Workplace: A 60-pound cylinder containing propane that was used for fueling a forklift truck was stored not only in the middle of the receiving bay without being secured but also in close proximity of the stairs leading to the upper mezzanine.
Recent events (2)
- — I (S) $811.3
- — Z (S) $1159
1910.303 B02
- Issued
- Oct 17, 2016
- Penalty
- Initial $1,159 · Current $811 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: Workplace: A re-locatable power tap (RPT), used to power few appliances was being overloaded.
Recent events (2)
- — I (S) $811.3
- — Z (S) $1159
1910.304 F01 IV
- Issued
- Oct 17, 2016
- Abate by
- Oct 25, 2016
- Penalty
- Initial $1,363 · Current $954 Reduced
General-duty citation text
29 CFR 1910.304(f)(1)(iv): Overcurrent devices shall be readily accessible to each employee or authorized building management personnel: Workplace: The electrical circuit breaker panel containing built in overcurrent devices was blocked by the rolls of carpet.
Recent events (2)
- — I (S) $954.1
- — Z (S) $1363