LITTLE ROCK, AR —
OSHA Inspection: ACCURATE BORING COMPANY
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of ACCURATE BORING COMPANY in 7500 REBSAMEN PARK ROAD, LITTLE ROCK, AR 72207 (NAICS 237110). OSHA activity number 341694768.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACCURATE BORING COMPANY
- Site address
- 7500 REBSAMEN PARK ROAD
- City
- LITTLE ROCK
- State
- AR
- ZIP
- 72207
- Mailing
- PO BOX 148, ALEXANDER, AR 72002
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 25
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.100 A
- Issued
- Nov 7, 2016
- Abate by
- Nov 22, 2016
- Penalty
- Initial $4,988 · Current $2,500 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: On or about, August 3, 2016, and at times prior thereto, employee(s) installing pipe splicers on 8-inch sewer pipe in an unprotected greater than 5 ft. in depth trench were not wearing protective helmets to prevent struck-by hazards.
Recent events (2)
- — I (S) $2500
- — Z (S) $4988
1926.651 C02
- Issued
- Nov 7, 2016
- Abate by
- Nov 22, 2016
- Penalty
- Initial $4,988 · Current $2,500 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: On or about August 3, 20016, and at times prior thereto, employee(s) installing pipe splicers on an 8-inch PVC sewer pipe inside an unprotected trench greater than 5 foot in depth had no safe means of egress.
Recent events (2)
- — I (S) $2500
- — Z (S) $4988
1926.651 I03
- Issued
- Nov 7, 2016
- Abate by
- Nov 22, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(i)(3): Sidewalks, pavements, or appurtenant structures had been undermined and a support system or another method was not provided to protect employees from the possible collapse of such structures: On or about August 3, 2016, and at times prior thereto, employees installing pipe splicers on 8-inch sewer pipe in a greater than 5 ft. in depth trench with no support system or other method used to protect them from possible collapse of the undermined asphalt pavement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.651 K01
- Issued
- Nov 7, 2016
- Abate by
- Nov 22, 2016
- Penalty
- Initial $4,988 · Current $2,500 Reduced
General-duty citation text
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions: On or about August 3, 2016, and at times prior thereto, for employees installing pipe splicers on 8-inch PVC sewer pipe in a trench 32 feet long, 9 feet wide, and greater than 5 feet in depth an inspection was not conducted by a competent person.
Recent events (2)
- — I (S) $2500
- — Z (S) $4988
1926.652 A01
- Issued
- Nov 7, 2016
- Abate by
- Nov 22, 2016
- Penalty
- Initial $4,988 · Current $2,500 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(b) or 1926.652(c): On or about August 3, 2016, and at times prior thereto, the employer did not protect employee(s) from cave-in hazards from the south and west when working in a greater than 5 foot in depth trench while installing pipe splicers on an 8-inch PVC sewer pipe.
Recent events (2)
- — I (S) $2500
- — Z (S) $4988
1926.652 B
- Issued
- Nov 7, 2016
- Abate by
- Nov 22, 2016
- Penalty
- Initial $4,988 · Current $2,500 Reduced
General-duty citation text
29 CFR 1926.652(b): The slopes and configurations of sloping and benching systems were not in accordance with the requirement options of 29 CFR 1926.652(b)(1), (b)(2), (b)(3), or (b)(4): On or about August 3, 2016, and at times prior thereto, the employer had not designed the sloping and benching for a trench greater than 5 feet in depth for employees installing pipe splicers on an 8-inch PVC sewer pipe, including but not limited to allowable slopes, configurations for sloping and benching, designed by a registered professional engineer. This condition exposed employees to cave-in hazards.
Recent events (2)
- — I (S) $2500
- — Z (S) $4988
More inspections in this industry (NAICS 237110)