Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SWIFT INDUSTRIES, INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of SWIFT INDUSTRIES, INC. in 3644 BURNETTE RD., SUWANEE, GA 30024 (NAICS 332812). OSHA activity number 341695914.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Swift Industries, INC. — free Get an email when a new federal OSHA severe-injury report for Swift Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3644 BURNETTE RD.
City
SUWANEE
State
GA
ZIP
30024
Mailing
3605 SWIFTWATER PARK DR., SUWANEE, GA 30024
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332812
Employees
115
Ownership type
A

8 citations on file for this inspection.

1910.23 E01

Serious Gravity 1 1 instance 5 exposed
Issued
Jan 26, 2017
Abate by
Feb 14, 2017
Penalty
Initial $4,889 · Current $3,178 Reduced
29 CFR 1910.23(e)(1): Standard railing(s) did not consist of top rail, intermediate rail and/or posts and/or did not have a vertical height of 42 inches (106.7 cm) nominal from upper surface of top rail to floor, platform runway, or ramp level:    On or about August 9, 2016, employees were exposed to fall hazards when the catwalk from the exit to the ground did not have a midrail.  The exit was located near the restrooms.    No abatement certification or documentation is required for this item.
Recent events (3)
  • — F (S) $3177.85
  • — C (S) $4889
  • — Z (S) $4889

1910.37 B04

Serious Gravity 1 1 instance 5 exposed
Issued
Jan 26, 2017
Abate by
Feb 14, 2017
Penalty
Initial $4,889 · Current $3,178 Reduced
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent:    On or about August 9, 2016, employees were exposed to fire hazards when the route out of the building was not apparent if one entered the office from the production area through the door marked as an exit.    No abatement certification or documentation is required for this item.
Recent events (3)
  • — F (S) $3177.85
  • — C (S) $4889
  • — Z (S) $4889

1910.37 B06

Serious Gravity 1 3 instances 5 exposed
Issued
Jan 26, 2017
Abate by
Feb 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color:  On or about August 9, 2016, employees were exposed to fire hazards when the exit signs were not lit. a. sign over the door from the production area to the office b. sign over the exit door closest to the restrooms  No abatement certification or documentation is required for this item.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.303 G02 I

Serious Gravity 1 1 instance 4 exposed
Issued
Jan 26, 2017
Abate by
Feb 14, 2017
Penalty
Initial $4,889 · Current $3,178 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    On or about August 9, 2016, employees were exposed to electric shock hazards when the water fountain housing had been damaged leaving a gap that exposed employees to electrical components inside of the housing.    No abatement certification or documentation is required for this item.
Recent events (3)
  • — F (S) $3177.85
  • — C (S) $4889
  • — Z (S) $4889

1910.141 A03 I

Other-than-serious 1 instance 4 exposed
Issued
Jan 26, 2017
Abate by
Feb 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.141(a)(3)(i): Places of employment were not kept clean to the extent that the nature of the work allowed:  On or about August 9, 2016, employees were exposed to unsanitary water when using the water fountain because the water fountain was not draining and there was a puddle of unsanitary water on top of the drain in the bowl that splashed up during drinking.  No abatement certification or documentation is required for this item.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.157 C01

Other-than-serious 1 instance 5 exposed
Issued
Jan 26, 2017
Abate by
Feb 22, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:   On or about August 9, 2016, the employer permitted the chairs in the office to limit access to the fire extinguisher located on the office wall.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.157 E02

Other-than-serious 1 instance 5 exposed
Issued
Jan 26, 2017
Abate by
Feb 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  On or about August 9, 2016, the employer had not regularly inspected the fire extinguishers located in the office and production area in the paint building.    No abatement certification or documentation is required for this item.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.178 L04 II D

Other-than-serious 1 instance 5 exposed
Issued
Jan 26, 2017
Abate by
Feb 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(4)(ii)(D): Refresher training in relevant topics was not provided to the operator when the operator was assigned to drive a different type of truck:  On or about August 9, 2016, the employer had not evaluated employees from MNDustries, Inc. who were permitted to use the forklift at the worksite.  No abatement certification or documentation is required for this item.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View Swift Industries, INC.'s full OSHA safety record →