WEBBERS FALLS, OK —
OSHA Inspection: U.S. ARMY CORPS OF ENGINEERS, TULSA DISTRICT
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of U.S. ARMY CORPS OF ENGINEERS, TULSA DISTRICT in 14300 POWERHOUSE ROAD, WEBBERS FALLS, OK 74470 (NAICS 221111). OSHA activity number 341697332.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. ARMY CORPS OF ENGINEERS, TULSA DISTRICT
- Site address
- 14300 POWERHOUSE ROAD
- City
- WEBBERS FALLS
- State
- OK
- ZIP
- 74470
- Mailing
- 14300 POWERHOUSE ROAD, WEBBERS FALLS, OK 74470
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 221111
- Employees
- 8
- Ownership type
- D
Citations
9 citations on file for this inspection.
1910.23 C01
- Issued
- Jan 31, 2017
- Abate by
- Feb 23, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards. a. On or about August 4, 2016 and at times prior to, at the upstream and land side of the generator bay, the open-sided floor lacked toeboards and exposes employees to struck-by hazards.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.305 A03 V
- Issued
- Jan 31, 2017
- Abate by
- Feb 23, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(a)(3)(v): Cable tray systems were used in hoistways or where subjected to severe physical damage. a. On or about August 4, 2016 and at times prior to, between generator 2 and 3, an electrical cable tray was in the hoist way of an overhead crane and was not protected from physical damage which exposes employees to electrical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1025 M01 II
- Issued
- Jan 31, 2017
- Penalty
- Initial $0 · Current $0
1591
General-duty citation text
29 CFR 1910.1025(m)(1)(ii): In classifying the hazards of lead at least the following hazards are to be addressed: Reproductive/developmental toxicity; central nervous system effects; kidney effects; blood effects; and acute toxicity effects.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.62 D01 III
- Issued
- Jan 31, 2017
- Abate by
- Feb 23, 2017
- Penalty
- Initial $0 · Current $0
1591
General-duty citation text
29 CFR 1926.62(d)(1)(iii): The employer did not collect personal samples representative of a full shift, including at least one sample for each job classification in each work area, either for each shift or for the shift with the highest exposure level: a. On or about August 4, 2016 and at times prior to, at the power plant, the employer did not require a contractor to collect personal samples to determine lead exposure during tasks which include, but are not limited to manual scraping, chemical stripping, needle gunning, and/or grinding of metal parts of turbines and generators where lead-containing coatings are present. b. On or about August 4, 2016 and at times prior to, at the power plant, the employer did not require a contractor to collect personal samples to determine lead exposure during tasks which include, but are not limited to torch cutting or torch heating of metal parts of turbines and generators where lead-containing coatings are present.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.62 H01
- Issued
- Jan 31, 2017
- Abate by
- Feb 23, 2017
- Penalty
- Initial $0 · Current $0
1591
General-duty citation text
29 CFR 1926.62(h)(1): "All surfaces shall be maintained as free as practicable of accumulations of lead".
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.305 B01 II
- Issued
- Jan 31, 2017
- Abate by
- Feb 23, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.416 A01
- Issued
- Jan 31, 2017
- Abate by
- Feb 23, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means: a. On or about August 4, 2016, by turbine 3 at the downstream wall, the raceway that held energized electrical cables lacked a cover and the energized electrical cables were not guarded to prevent employee contact which exposes employees to electrical hazards. b. On or about August 4, 2016, by turbine 1 at the downstream wall, the raceway that held energized electrical cables lacked a cover and the energized electrical cables were not guarded to prevent employee contact which exposes employees to electrical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1127 D01 I
- Issued
- Jan 31, 2017
- Abate by
- Feb 23, 2017
- Penalty
- Initial $0 · Current $0
C141
General-duty citation text
29 CFR 1926.1127(d)(1)(i): The employer did not establish the applicability of this standard by determining whether cadmium was present in the work place and whether there was the possibility that employee exposure will be at or above the action level prior to performance of any construction work: a. On or about August 4, 2016, and at times prior to, power plant, the employer did not require a contractor to establish the applicability of the standard, did not determine that cadmium was present in paint-primer on turbine parts including but not limited to servo motors, and did not determine whether there was the possibility that contractor employee exposures would be at or above the cadmium action level during manual scraping, chemical stripping, grinding, needle gunning, and torch heating or cutting painted metal turbine parts.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1027 K01
- Issued
- Jan 31, 2017
- Abate by
- Feb 23, 2017
- Penalty
- Initial $0 · Current $0
C141
General-duty citation text
29 CFR 1910.1027(k)(1): All surfaces shall be maintained as free as practicable of accumulations of cadmium.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at U.S. Army Corps of Engineers, Tulsa District
View U.S. Army Corps of Engineers, Tulsa District's full OSHA safety record →
More inspections in this industry (NAICS 221111)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341697332.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.