Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MCCORMICK INDUSTRIAL ABATEMENT SERVICES, INC

Unprogrammed Other inspection · Health discipline

On , OSHA opened an unprogrammed Other health inspection of MCCORMICK INDUSTRIAL ABATEMENT SERVICES, INC in 14300 POWERHOUSE ROAD, WEBBERS FALLS, OK 74470 (NAICS 562910). OSHA activity number 341698314.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mccormick Industrial Abatement Services, INC — free Get an email when a new federal OSHA severe-injury report for Mccormick Industrial Abatement Services, INC is published. One employer, no account, unsubscribe in one click.
Site address
14300 POWERHOUSE ROAD
City
WEBBERS FALLS
State
OK
ZIP
74470
Mailing
1421 E. 9TH STREET, LITTLE ROCK, AR 72202
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562910
Employees
6
Ownership type
A

11 citations on file for this inspection.

1910.23 C01

Serious Gravity 1 1 instance 6 exposed
Issued
Jan 31, 2017
Abate by
Feb 23, 2017
Penalty
Initial $3,802 · Current $2,281 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:    a.  On or about August 4, 2016, at the upstream and land side of the generator bay, the open-sided floor lacked toeboards and exposes employees to struck-by hazards.
Recent events (2)
  • — I (S) $2281.2
  • — Z (S) $3802

1910.134 C01 V

Serious Gravity 5 1 instance 6 exposed
Issued
Jan 31, 2017
Abate by
Feb 23, 2017
Penalty
Initial $6,338 · Current $3,803 Reduced

Hazardous substances 1591

29 CFR 1910.134(c)(1)(v): The written program did not contain procedures and schedules for cleaning, disinfecting, storing, inspecting, repairing, discarding, and otherwise maintaining respirators: (Construction Reference 1926.103)   a.  On or about August 4, 2016, the written respiratory protection program did not contain procedures for cleaning, disinfecting, storing, inspecting, discarding, and otherwise maintaining tight fitting respirators.  Employees wore half mask respirators for lead cleanup and were exposed to lead hazards.
Recent events (2)
  • — I (S) $3802.8
  • — Z (S) $6338

1910.134 H02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 31, 2017
Abate by
Feb 23, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 1591

29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or  were not packed or stored to prevent deformation of the facepiece and exhalation valve:  (Construction Reference 1926.103)    a.  On or about August 4, 2016, turbine bay, by the upstream wall, an uncovered half mask respirator hanging from a rack was contaminated with lead and exposes employees to lead hazards.      b.  On or about August 4, 2016, generator bay, between generator 2 and 3, an uncovered half mask respirator on the top surface of a metal cabinet, was contaminated with lead and exposes employees to lead hazards.      c.  On or about August 4, 2016, equipment gallery, at the upstream wall below the turbine 2, an uncovered half mask respirator hung at scaffolding and pipes where lead containing debris was present and was not protected from lead contamination and exposes employees to lead hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F02

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 31, 2017
Abate by
Feb 23, 2017
Penalty
Initial $6,338 · Current $3,803 Reduced

Hazardous substances 1591

29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested: (Construction Reference 1926.103)    a.  On or about August 4, 2016, at the erection deck and overhead turbine bay areas, an employee was required to wear a tight-fitting respirator during lead cleanup work and the employer did not ensure an annual respirator fit test was provided.  Power plant surfaces were contaminated with lead which exposed employees lead hazards.
Recent events (2)
  • — I (S) $3802.8
  • — Z (S) $6338

1910.134 G01 I A

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 31, 2017
Abate by
Feb 23, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 1591

29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: (Construction Reference 1926.103)    a.  On or about August 19, 2016, at the generator bay, an employee had facial hair between the sealing surface of the tight-fitting respirator facepiece and the face during lead cleanup work which exposes employees to lead hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 M02 II

Serious Gravity 5 2 instances 3 exposed
Issued
Jan 31, 2017
Abate by
Feb 23, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 1591

29 CFR 1910.134(m)(2)(ii): Fit test records were not retained for respirator users until the next fit test was administered:  (Construction Reference 1926.103)    a.  On or about August 4, 2016, at the erection deck and overhead turbine bay areas, an employee was required to wear a tight-fitting respirator during lead cleanup work and the employer did not retain respirator fit test records until the next respirator fit was administered.  Power plant surfaces were contaminated with lead which exposed employees lead hazards.       b.  On or about August 19, 2016, at the generator bays, two employees were required to wear tight-fitting respirators for lead cleanup work and the employer did not retain respirator fit test records until the next respirator fit tests were administered.  Power plant surfaces were contaminated with lead which exposed employees to lead hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.62 D01 III

Serious Gravity 5 1 instance 6 exposed
Issued
Jan 31, 2017
Abate by
Feb 23, 2017
Penalty
Initial $6,338 · Current $3,803 Reduced

Hazardous substances 1591

29 CFR 1926.62(d)(1)(iii): The employer did not collect personal samples representative of a full shift, including at least one sample for each job classification in each work area, either for each shift or for the shift with the highest exposure level:    a.  On or about August 4, 2016 and at times prior to, at the power plant, the employer did not collect personal samples to determine employee lead exposure during tasks which include, but are not limited to manual scraping and chemical stripping of metal parts of turbines and generators where lead-containing coating is present.
Recent events (2)
  • — I (S) $3802.8
  • — Z (S) $6338

1926.62 H01

Serious Gravity 5 5 instances 6 exposed
Issued
Jan 31, 2017
Abate by
Feb 23, 2017
Penalty
Initial $6,338 · Current $3,803 Reduced

Hazardous substances 1591

29 CFR 1926.62(h)(1): All surfaces were not maintained as free as practicable of accumulations of lead:    a.  On or about August 4, 2016, at the erection bay, surfaces which include, but are not limited to the railing and floor, were not maintained as free as practicable of accumulations of lead.      b.  On or about August 4, 2016, at the turbine bay, surfaces which include, but are not limited to the following, were not maintained as free as practicable of accumulations of lead:          -  Locker 33 at riverside wall by turbine bay 3      -  Vacuum near locker 33      -  Electrical box near upstream wall by turbine bay 3     c.  On or about August 4, 2016, at the stairs between the generator bay and the control room, surfaces which include, but are not limited to the top of electrical MCC 8P, was not maintained as free as practicable of accumulations of lead.     d.  On or about August 4, 2016, by generator 2, surfaces which include, but are not limited to the following, were not maintained as free as practicable of accumulations of lead:          -  Top surface of tan cabinet      -  Floor under speed increaser      -  Floor near access to generator 2 pit     e.  On or about August 5, 2016, equipment gallery, surfaces which include, but are not limited to horizontal pipes and the floor were not maintained as free as practicable of accumulations of lead.
Recent events (2)
  • — I (S) $3802.8
  • — Z (S) $6338

1926.416 A01

Serious Gravity 5 2 instances 6 exposed
Issued
Jan 31, 2017
Abate by
Feb 23, 2017
Penalty
Initial $6,338 · Current $3,803 Reduced
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:    a.  On or about August 4, 2016, by turbine 3 at the downstream wall, the raceway that held energized electrical cables lacked a cover and the energized electrical cables were not guarded to prevent employee contact which exposes employees to electrical hazards.      b.  On or about August 4, 2016, by turbine 1 at the downstream wall, the raceway that held energized electrical cables lacked a cover and the energized electrical cables were not guarded to prevent employee contact which exposes employees to electrical hazards.
Recent events (2)
  • — I (S) $3802.8
  • — Z (S) $6338

1926.1127 D01 I

Serious Gravity 5 1 instance 6 exposed
Issued
Jan 31, 2017
Abate by
Feb 23, 2017
Penalty
Initial $6,338 · Current $3,803 Reduced

Hazardous substances C141

29 CFR 1926.1127(d)(1)(i): The employer did not establish the applicability of this standard by determining whether cadmium was present in the work place and whether there was the possibility that employee exposure will be at or above the action level prior to performance of any construction work:    a.  On or about August 4, 2016, and at times prior to, at the power plant, the employer did not establish the applicability of the standard, did not determine that cadmium was present in paint-primer on turbine parts including but not limited to servo motors, and did not determine whether there was the possibility that employee exposures would be at or above the cadmium action level during manual scraping and chemical stripping of painted metal parts.
Recent events (2)
  • — I (S) $3802.8
  • — Z (S) $6338

1926.1127 K01

Serious Gravity 5 4 instances 6 exposed
Issued
Jan 31, 2017
Abate by
Feb 23, 2017
Penalty
Initial $0 · Current $0

Hazardous substances C141

29 CFR 1926.1127(k)(1): All surfaces were not maintained as free as practical of accumulations of cadmium:    a.  On or about August 4, 2016, at the turbine bay, surfaces which include, but are not limited to the following, were not maintained as free as practicable of accumulations of cadmium:          -  Locker 33 at riverside wall by turbine bay 3      -  Vacuum near locker 33       b.  On or about August 4, 2016, at the stairs between the generator bay and the control room, surfaces which include, but are not limited to the top of electrical MCC 8P, was not maintained as free as practicable of accumulations of cadmium.     c.  On or about August 4, 2016, by generator 2, surfaces which include, but are not limited to the following, were not maintained as free as practicable of accumulations of cadmium:          -  Top surface of tan cabinet      -  Floor near access to generator 2 pit      d.  On or about August 5, 2016, equipment gallery, surfaces which include, but are not limited to the floor were not maintained as free as practicable of accumulations of cadmium.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Mccormick Industrial Abatement Services, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341698314.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.