WEST BATH, ME —
OSHA Inspection: EAST COAST WOODWORKING, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of EAST COAST WOODWORKING, INC. in 56 NEW MEADOWS ROAD, WEST BATH, ME 04530 (NAICS 337212). OSHA activity number 341698900.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EAST COAST WOODWORKING, INC.
- Site address
- 56 NEW MEADOWS ROAD
- City
- WEST BATH
- State
- ME
- ZIP
- 04530
- Mailing
- 56 NEW MEADOWS ROAD, WEST BATH, ME 04530
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337212
- Employees
- 14
- Ownership type
- A
Citations
17 citations on file for this inspection.
1910.23 C01
- Issued
- Sep 26, 2016
- Abate by
- Oct 4, 2016
- Penalty
- Initial $3,563 · Current $1,782 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent): Finishing Area - The platform above the spray room, approximately 9' 6" from the floor was not guarded with standard railings.
Recent events (2)
- — I (S) $1782
- — Z (S) $3563
1910.157 E02
- Issued
- Sep 26, 2016
- Abate by
- Oct 6, 2016
- Penalty
- Initial $2,138 · Current $1,069 Reduced
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: Finish Area - The two Pyro Chem and one Amerex all purpose fire extinguishers were not visually inspected at least monthly.
Recent events (2)
- — I (S) $1069
- — Z (S) $2138
1910.157 E03
- Issued
- Sep 26, 2016
- Abate by
- Oct 6, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: Finish Area - The two Pyro Chem and one Amerex all purpose fire extinguishers were not subjected to an annual maintenance check since 2013.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 C01
- Issued
- Sep 26, 2016
- Abate by
- Oct 6, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: Finish Area - The two PyroChem and one Amerex fire extinguishers were not mounted.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L06
- Issued
- Sep 26, 2016
- Abate by
- Oct 14, 2016
- Penalty
- Initial $2,850 · Current $1,425 Reduced
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): At the Facility - The employer did not certify that the operator has been trained and evaluated .
Recent events (2)
- — I (S) $1425
- — Z (S) $2850
1910.178 P01
- Issued
- Sep 26, 2016
- Abate by
- Oct 6, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): The Clark forklift, model GPS 25-16MC, serial #GP138MC/15-8880KF was found to be in need of repair, in the following instances: a) Yard - Defective horn. b) Yard - Defective strobe. c) Yard - Defective back-up alarm. d) Yard - Parts of the accelerator pedal were missing.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Sep 26, 2016
- Abate by
- Oct 4, 2016
- Penalty
- Initial $3,563 · Current $1,782 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Cabinetmaking Area - The Jet drill press did not have guard for the rotating chuck and bits.
Recent events (2)
- — I (S) $1782
- — Z (S) $3563
1910.213 C01
- Issued
- Sep 26, 2016
- Abate by
- Oct 6, 2016
- Penalty
- Initial $3,563 · Current $1,782 Reduced
General-duty citation text
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: In the following instances, circular handfed ripsaw(s) were not guarded by an automatically adjusting hood: a) Cabinetmaking Area - The Jet table saw b) Cabinetmaking Area - The Panel saw
Recent events (2)
- — I (S) $1782
- — Z (S) $3563
1910.213 C02
- Issued
- Sep 26, 2016
- Abate by
- Oct 6, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator: In the following instances, hand-fed circular ripsaws were not furnished with a spreader: a) Cabinetmaking Area - The Jet tablesaw b) Cabinetmaking Area - The Panel tablesaw
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 J03
- Issued
- Sep 26, 2016
- Abate by
- Oct 6, 2016
- Penalty
- Initial $3,563 · Current $1,782 Reduced
General-duty citation text
29 CFR 1910.213(j)(3): Hand-fed jointer(s) with horizontal cutting head(s) did not have automatic guard(s) which automatically adjusted to cover the unused portion of the head and/or remained in contact with the material at all times: Cabinetmaking Area - The Jet hand-fed jointer did not have a guard that automatically adjusted to cover the unused portion of the head and/or remained in contact with the material at all times.
Recent events (2)
- — I (S) $1782
- — Z (S) $3563
1910.213 H01
- Issued
- Sep 26, 2016
- Abate by
- Oct 4, 2016
- Penalty
- Initial $3,563 · Current $1,781 Reduced
General-duty citation text
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the stock: Scrap Cutting Area - The lower exposed portion of the Delta radial arm saw blade was inadequately guarded because the guard did not automatically adjust itself to the thickness of the stock and remained in contact with the stock.
Recent events (2)
- — I (S) $1781
- — Z (S) $3563
1910.213 H04
- Issued
- Sep 26, 2016
- Abate by
- Oct 6, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(h)(4): Radial saw(s) were not installed in a manner so as to cause the cutting head to return gently to the starting position when released by the operator: Scrap Cutting Area - The Delta radial arm saw did not gently return to the starting position when released.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.304 G05
- Issued
- Sep 26, 2016
- Penalty
- Initial $3,563 · Current $1,781 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: Cabinetmaking Area - The path to ground from the yellow extension cord connected to the Protemp fan was not permanent, continuous, and effective.
Recent events (2)
- — I (S) $1781
- — Z (S) $3563
1910.1200 E01
- Issued
- Sep 26, 2016
- Abate by
- Oct 21, 2016
- Penalty
- Initial $3,563 · Current $1,780 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): Finishing Area - The employer had not developed a written hazard communication program.
Recent events (2)
- — I (S) $1780
- — Z (S) $3563
1910.22 D01
- Issued
- Sep 26, 2016
- Abate by
- Oct 14, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate: The loads approved by the building official for the storage and office areas were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate, in the following instances: a) Storage area above the Repair and Spray Room b) Storage area adjacent to the upstairs office c) Second floor office area
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 C02 II
- Issued
- Sep 26, 2016
- Abate by
- Nov 28, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: Finish Area - The employer did not ensure that the employee who voluntarily wore the elastomeric half-face respirator was medically able to use the respirator.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.151 C
- Issued
- Sep 26, 2016
- Abate by
- Nov 28, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: Finishing Area - Where employees were exposed to ML Campbell Care Catatyst C1491 and Duravar Plus Cataylzed Finish, suitable eye washing facilities were not provided.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at East Coast Woodworking, INC.
View East Coast Woodworking, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 337212)
More inspections in ME
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341698900.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.