Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: STORM PORT BOAT WORKS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STORM PORT BOAT WORKS, INC. in 5721 CHAMBERLAN POOL AVE, HOMOSASSA, FL 34448 (NAICS 336612). OSHA activity number 341700961.

Watch Storm Port Boat Works, INC. — free Get an email when a new federal OSHA severe-injury report for Storm Port Boat Works, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5721 CHAMBERLAN POOL AVE
City
HOMOSASSA
State
FL
ZIP
34448
Mailing
6860 S. HOLLY OAK PT, HOMOSASSA, FL 34448
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336612
Employees
1
Ownership type
A

5 citations on file for this inspection.

1910.303 B07 I

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1604.00 · Current $962.00 Reduced
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment:  a.  In the storage room, the breaker panel cover was missing, exposing an employee to an electrical shock hazard, on or about 8/15/16.
Recent events (2)
  • — I (S) $962.4
  • — Z (S) $1604

1910.157 C01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  a. Near the front entrance, the portable fire extinguisher was sitting on the floor next to a table and there was nothing marking the location of the portable fire extinguisher, on or about 8/15/16.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B02 I

Other-than-serious 5 instances 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  a. In the shop area, wall outlet boxes and light switch boxes were missing cover plates, exposing an employee to an electrical shock hazard, on or about 8/15/16.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G02 III

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  a. In the shop area, the blue extension cord did not have a strain relief attached, exposing an employee to an electrical shock hazard, on or about 8/15/16.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.334 A02 I

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  a. In the shop area, the power cord on the green hand held circular saw was damaged and covered with black electrical tape, exposing an employee to an electrical shock hazard, on or about 8/15/16.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341700961.