INVERNESS, FL —
OSHA Inspection: FLORAL CITY AIRBOAT COMPANY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FLORAL CITY AIRBOAT COMPANY, INC. in 5098 SOUTH FLORIDA AVE, INVERNESS, FL 34450 (NAICS 336612). OSHA activity number 341701027.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FLORAL CITY AIRBOAT COMPANY, INC.
- Site address
- 5098 SOUTH FLORIDA AVE
- City
- INVERNESS
- State
- FL
- ZIP
- 34450
- Mailing
- 5098 SOUTH FLORIDA AVE, INVERNESS, FL 34450
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336612
- Employees
- 2
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.215 A04
- Issued
- Aug 24, 2016
- Abate by
- Sep 6, 2016
- Penalty
- Initial $1,604 · Current $962 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: a. In the shop area, the work rest on the Dayton bench grinder was set at 1 inch, exposing an employee to a struck by hazard, on or about 8/16/16.
Recent events (2)
- — I (S) $962.4
- — Z (S) $1604
1910.215 B09
- Issued
- Aug 24, 2016
- Abate by
- Sep 6, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a. In the shop area, the Dayton bench grinder did not have the tongue guard installed, exposing an employee to a struck by hazard, on or about 8/16/16.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.243 C03
- Issued
- Aug 24, 2016
- Abate by
- Sep 6, 2016
- Penalty
- Initial $2,672 · Current $1,603 Reduced
General-duty citation text
29 CFR 1910.243(c)(3): Abrasive wheels used on vertical portable grinder(s) (right angle head grinders) were not provided with safety guard(s) having a maximum exposure angle of 180 degrees and located between the operator and wheel: a. In the shop area, the handheld DeWalt angle grinder did not have guards installed, exposing an employee to an amputation hazard, on or about 8/16/16.
Recent events (2)
- — I (S) $1603.2
- — Z (S) $2672
1910.303 B02
- Issued
- Aug 24, 2016
- Abate by
- Sep 6, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a. In the shop area, the metal junction box used to supply power to the Dayton bench grinder was not permanently mounted, exposing an employee to an electrical shock hazard, on or about 8/16/16.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B02 I
- Issued
- Aug 24, 2016
- Abate by
- Sep 6, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: a. Along the south wall in the lobby area, the wall outlet cover was missing, exposing employees to an electrical shock hazard, on or about 8/16/16.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G02 III
- Issued
- Aug 24, 2016
- Abate by
- Sep 6, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws: a. In the shop area, near the Dayton bench grinder, the yellow power cord for the metal junction box and the power cord for the HUTH MFG. binder did not have the strain relief attached, exposing an employee to an electrical shock hazard, on or about 8/16/16.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 336612)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341701027.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.