OSHA Inspection: ARKEMA, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ARKEMA, INC. in 18000 CROSBY EASTGATE RD., CROSBY, TX 77532 (NAICS 325199). OSHA activity number 341701282.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Arkema, INC. — free Get an email when a new federal OSHA severe-injury report for Arkema, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ARKEMA, INC.
Site address
18000 CROSBY EASTGATE RD.
City
CROSBY
State
TX
ZIP
77532
Mailing
18000 CROSBY EASTGATE RD., CROSBY, TX 77532
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325199
Employees
52
Ownership type
A

10 citations on file for this inspection.

1910.22 B01

Serious Gravity 1 1 instance 8 exposed
Issued
Feb 8, 2017
Abate by
Feb 28, 2017
Penalty
Initial $5,975 · Current $5,078 Reduced
29 CFR 1910.22(b)(1): Aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard.    On or about August 9th 2016 in the Multi-Purpose Unit at Arkema, Inc. located in Crosby, TX, the employer did not keep aisles and passageways in good repair.
Recent events (2)
  • — I (S) $5078
  • — Z (S) $5975

1910.119 D03 I B

Serious Gravity 1 3 instances 8 exposed
Issued
Feb 8, 2017
Abate by
Feb 28, 2017
Penalty
Initial $5,975 · Current $5,078 Reduced
29 CFR 1910.119(d)(3)(i)(B): The employer's piping and instrument diagrams were not accurate and did not represent equipment that was existing and was part of the process.      On or about August 9th 2016 in the Multi-Purpose Unit at Arkema, Inc. located in Crosby, TX, the employer did not ensure piping and instrument diagrams were accurate and presented equipment that was existing and was part of the process, such as but not limited to the following piping and instrument diagrams:    a)  P&ID CR-30-X0200  b)  P&ID CR-30-X0209  c)  P&ID CR-30-X0210
Recent events (2)
  • — I (S) $5078
  • — Z (S) $5975

1910.119 E01

Serious Gravity 10 3 instances 8 exposed
Issued
Feb 8, 2017
Abate by
May 31, 2017
Penalty
Initial $12,675 · Current $10,773 Reduced
29 CFR 1910.119(e)(1): The process hazard analysis was not appropriate to the complexity of the process and did not identify, evaluate, and control the hazards involved in the process.      This violation was most recently observed on or about August 9, 2016 in the Multi-Purpose Unit at Arkema, Inc. located in Crosby, Texas when the employer did not identify, evaluate and control the hazards of the process that were introduced by the atmospheric discharge from the pressure relief devices on the Sulfur Dioxide tank and KC-1 and KC3.  The discharge point was found to be within 2 feet from the operator walkway.
Recent events (2)
  • — I (S) $10773
  • — Z (S) $12675

1910.119 G02

Serious Gravity 5 1 instance 8 exposed
Issued
Feb 8, 2017
Abate by
Feb 28, 2017
Penalty
Initial $9,959 · Current $8,465 Reduced
29 CFR 1910.119(g)(2): Refresher training was not provided at least every three years, and more often if necessary, to each employee involved in operating a process to assure that the employee understood and adhered to the current operating procedures of the process.     On or about August 9th 2016 in the Multi-Purpose Unit at Arkema, Inc. located in Crosby, TX, the employer data did not provide refresher training at least every three years, and more often if necessary, to each employee involved in operating a process to assure that the employee understood and adhered to the current operating procedures of the process.
Recent events (2)
  • — I (S) $8465
  • — Z (S) $9959

1910.119 J02

Serious Gravity 10 2 instances 8 exposed
Issued
Feb 8, 2017
Abate by
Feb 28, 2017
Penalty
Initial $12,675 · Current $10,773 Reduced
29 CFR 1910.119(j)(2): The employer did not implement written procedures to maintain the on-going integrity of process equipment.    On or about August 9th 2016 in the Multi-Purpose Unit at Arkema, Inc. located in Crosby, TX and at times prior thereto and after, where the employer failed to implement written procedures to maintain the on-going integrity of process equipment, including but not limited to the following equipment:                   a)  SO2 detector(s) located at SO2 tank              b)  LEL detector(s) in Building 30 by T-24
Recent events (2)
  • — I (S) $10773
  • — Z (S) $12675

1910.119 J04 I

Serious Gravity 10 11 instances 8 exposed
Issued
Feb 8, 2017
Abate by
Feb 28, 2017
Penalty
Initial $12,675 · Current $10,773 Reduced
29 CFR 1910.119(j)(4)(i): The employer did not perform inspection and tests on process equipment.    On or about August 9th 2016 in the Multi-Purpose Unit at Arkema, Inc. located in Crosby, TX inspections and tests were not performed on process equipment, that include but are not limited to the following:     a)    SO2 detector(s) located at SO2 tank    b)    LEL detector(s) in Building 30 by T-24,   c)     LT-4183,   d)    LT-4061   e)    TI/TT-4404,    f)     TI/TT-4403,    g)    TI/TT-4136,    h)    TI-4086A,    i)      TI-4086B, and  j)     Pipeline 1 ½ -CP-1399-316L from 17-T-19 (Sulfur dioxide tank) to EH-4 (SO2 Vaporizer)  k)    Pipeline 1-P301009-P from Pump P-63A(P&ID CR-30-X-0012 Rev. D) to Heat Exchanger 31-EH-14 (P&ID CR-30-X-0100 Rev. B)
Recent events (2)
  • — I (S) $10773
  • — Z (S) $12675

1910.119 J04 II

Serious Gravity 10 4 instances 8 exposed
Issued
Feb 8, 2017
Abate by
Feb 28, 2017
Penalty
Initial $12,675 · Current $10,773 Reduced
29 CFR 1910.119(j)(4)(ii): Inspection and testing procedures did not follow recognized and generally accepted good engineering practices.     On or about August 9th 2016 in the Multi-Purpose Unit at Arkema, Inc. located in Crosby, TX, the employer data did not include minimum thickness/required thickness and establish corrosion rates according to recognized and generally accepted good engineering practices, such as America Petroleum Institute (API) 510 section 5 and 7 (Pressure Vessel Code: In-service Inspection, Rating, Repair, and Alteration).  Equipment include but is not limited to the following:    a)    Hydrogen Peroxide T-63, constructed 2013 (P&ID CR-30-X-0012 Rev. D)    b)    Sulfur Dioxide T-19, constructed in 1978 (P&ID CR 17-X-0017 Rev. D)    c)    Reactor KC-1, constructed in 1992 (P&ID CR-30-X-0104 Rev.B )    d)    Isobutylene/T-Amylene Sulfation Tank T-24, constructed in 1993 (P&ID CR-X-0203 Rev. E)
Recent events (2)
  • — I (S) $10773
  • — Z (S) $12675

1910.119 J04 III

Serious Gravity 10 3 instances 8 exposed
Issued
Feb 8, 2017
Abate by
Feb 28, 2017
Penalty
Initial $12,675 · Current $10,773 Reduced
29 CFR 1910.119(j)(4)(iii): The frequency of inspections and tests of process equipment was not consistent with applicable manufacturers' recommendations and good engineering practices, and more frequently if determined to be necessary by prior operating experience.    On or about August 9th 2016 in the Multi-Purpose Unit at Arkema, Inc. located in Crosby, TX, the frequency of inspections and tests of process equipment was not consistent with applicable manufacturers' recommendations and good engineering practices, and more frequently if determined to be necessary by prior operating experience.  Equipment includes but is not limited to:    a)    Sulfur Dioxide T-19 (P&ID CR 17-X-0017 Rev. D)  b)    Pipeline 1 ½-CP-1399-316L (P&ID CR-17-X-0017 Rev D) from 17-T-19 (Sulfur dioxide tank) to EH-4 (SO2 Vaporizer) ( P&ID CR-30-X-0021)   c)     Pipeline 1-P301009-P from Pump P-63A(P&ID CR-30-X-0012 Rev. D) to Heat Exchanger 31-EH-14 (P&ID CR-30-X-0100 Rev. B)
Recent events (2)
  • — I (S) $10773
  • — Z (S) $12675

1910.119 J05

Serious Gravity 10 2 instances 8 exposed
Issued
Feb 8, 2017
Abate by
Feb 28, 2017
Penalty
Initial $12,675 · Current $10,773 Reduced
29 CFR 1910.119(j)(5): The employer did not correct deficiencies in equipment that are outside acceptable limits before further use or in a safe and timely manner when necessary means are taken to assure safe operation.    On April 9, 2016 and at times prior thereto, at the Arkema, Inc in Crosby, TX, the employer did not correct deficiencies in process equipment when safety systems were not working as designed before further use including but not limited to the following:    a)    SO2 detector(s) located at SO2 tank  b)    LEL detector(s) in Building 30 by T-24
Recent events (2)
  • — I (S) $10773
  • — Z (S) $12675

1910.307 C

Serious Gravity 5 2 instances 8 exposed
Issued
Feb 8, 2017
Abate by
Feb 28, 2017
Penalty
Initial $9,959 · Current $8,465 Reduced
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location:       On or about August 9th 2016 in the Multi-Purpose Unit at Arkema, Inc located in Crosby, TX, the employer did not ensure that equipment was safe for the hazardous location.
Recent events (2)
  • — I (S) $8465
  • — Z (S) $9959

View Arkema, INC.'s full OSHA safety record →