Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SALEM RV CENTER, INCORPORATED

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SALEM RV CENTER, INCORPORATED in 387 CLIFFORD ROAD, SELINSGROVE, PA 17870 (NAICS 441210). OSHA activity number 341701340.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Salem RV Center, Incorporated — free Get an email when a new federal OSHA severe-injury report for Salem RV Center, Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
387 CLIFFORD ROAD
City
SELINSGROVE
State
PA
ZIP
17870
Mailing
387 CLIFFORD ROAD, SELINSGROVE, PA 17870
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441210
Employees
14
Ownership type
A

3 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 6 exposed
Issued
Aug 30, 2016
Penalty
Initial $3,563 · Current $2,500 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toe boards:     a) Production Area:  The storage loft located approximately eighty-seven (87) inches high above ground level where RV camper materials are stored and accessible by employees, was not equipped with standard railings, exposing employees to fall hazards, as observed on or about August 16, 2016.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $3563

1910.23 D01 III

Serious Gravity 5 1 instance 6 exposed
Issued
Aug 30, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.23(d)(1)(iii): Stairway(s) less than 44 inches wide having both sides open, did not have one stair railing on each side:    a) Production Area:  The stairway leading to the storage loft measured about twenty-four (24) inches in width and consisting of 12 risers was not equipped with standard railings, exposing employees to fall hazards, as observed on or about August 16, 2016.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 J02 IV

Serious Gravity 1 4 instances 6 exposed
Issued
Aug 30, 2016
Penalty
Initial $2,138 · Current $1,000 Reduced
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location:    a) Outside the garage area: Leviton power receptacles (30 amp, 125 volt) used for RV campers during servicing were not equipped with weatherproof enclosures, exposing employees to electrical hazards as observed on or about August 16, 2016.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2138

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341701340.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.