BELLEVUE, NE —
OSHA Inspection: CORESLABSTRUCTURES, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of CORESLABSTRUCTURES, INC. in 802 ALLIED RD, BELLEVUE, NE 68123 (NAICS 327390). OSHA activity number 341709798.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CORESLABSTRUCTURES, INC.
- Site address
- 802 ALLIED RD
- City
- BELLEVUE
- State
- NE
- ZIP
- 68123
- Mailing
- 802 ALLIED RD, BELLEVUE, NE 68123
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327390
- Employees
- 210
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.305 G01 IV
- Issued
- Feb 3, 2017
- Penalty
- Initial $3,531 · Current $2,118 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv)(a): Flexible extension cord(s) for a scale in the Acid building were wrapped around conduit and attached with zip strips.
Recent events (2)
- — I (S) $2118
- — Z (S) $3531
1910.1026 C
- Issued
- Feb 3, 2017
- Abate by
- Jun 16, 2017
- Penalty
- Initial $6,926 · Current $4,155 Reduced
0689
General-duty citation text
29 CFR 1910.1026(c): Employees were exposed to an airborne concentration of chromium (VI) which exceeded 5 micrograms per cubic meter of air, as an 8-hour time-weighted average: The employer did not ensure that employee exposure to hexavalent chromium did not exceed 5 micrograms per cubic meter (ug/m3), as an 8 hour time weighted average (TWA). This violation occurred on or about September 28, 2016 in the welding/fabrication shop when stainless steel welding exposed an employee to hexavalent chromium at an 8 hour TWA of 13.6 ug/m3, approximately 2.7 time the PEL of 5.0 ug/m3. Sampling was performed for 385 minutes and zero exposure was assumed for the 95 minutes not sampled.
Recent events (2)
- — I (S) $4155
- — Z (S) $6926
1910.1026 F01 I
- Issued
- Feb 3, 2017
- Abate by
- Jun 16, 2017
- Penalty
- Initial $0 · Current $0
0689
General-duty citation text
29 CFR 1910.1026(f)(1)(i): Feasible engineering controls and work practices were not instituted to reduce and maintain employee exposures to chromium (VI) at or below the permissible exposure limit: The employer did not ensure that engineering controls, such as exhaust ventilation, and work practices lowered employee exposure to hexavalent chromium below 5 micrograms per cubic meter (ug/m3), as an 8 hour time weighted average (TWA). This violation occurred on or about September 28, 2016 in the welding/fabrication shop when stainless steel welding exposed an employee to hexavalent chromium at an 8 hour TWA of 13.6 ug/m3, approximately 2.7 times the PEL of 5.0 ug/m3. Sampling was performed for 385 minutes and zero exposure was assumed for the 95 minutes not sampled.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1026 D02 I
- Issued
- Feb 3, 2017
- Abate by
- Jun 16, 2017
- Penalty
- Initial $6,926 · Current $4,155 Reduced
0689
General-duty citation text
29 CFR 1910.1026(d)(2)(i): The employer did not perform initial monitoring to determine the 8-hour time-weighted average exposure to chromium (VI) for each employee on the basis of a sufficient number of personal breathing zone air samples to accurately characterize full shift exposure on each shift, for each job classification, in each work area: The employer did not ensure that employee(s) in the weld/fabrication shop, exposed to hexavalent chromium from welding or other hot work on chromium containing steel, were properly monitored to determine their 8-hour time-weighted average exposure levels.
Recent events (2)
- — I (S) $4155
- — Z (S) $6926
1910.1026 L01 I
- Issued
- Feb 3, 2017
- Abate by
- Mar 23, 2017
- Penalty
- Initial $5,542 · Current $3,325 Reduced
0689
General-duty citation text
29 CFR 1910.1026(l)(2)(i): The employer did not ensure that all employees who were assigned to workplaces where there was exposure to chromium (VI) were provided with information and training as required by the Hazard Communication standard, 29 CFR 1910.1200: The employer did not ensure that employee(s) in the weld/fabrication shop, exposed to hexavalent chromium from welding or other hot work on chromium containing steel, were properly were properly trained on the hazards, health effects, and the contents of this section.
Recent events (2)
- — I (S) $3325
- — Z (S) $5542
More inspections in this industry (NAICS 327390)