Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CORESLABSTRUCTURES, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of CORESLABSTRUCTURES, INC. in 802 ALLIED RD, BELLEVUE, NE 68123 (NAICS 327390). OSHA activity number 341709798.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Coreslabstructures, INC. — free Get an email when a new federal OSHA severe-injury report for Coreslabstructures, INC. is published. One employer, no account, unsubscribe in one click.
Site address
802 ALLIED RD
City
BELLEVUE
State
NE
ZIP
68123
Mailing
802 ALLIED RD, BELLEVUE, NE 68123
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327390
Employees
210
Ownership type
A

5 citations on file for this inspection.

1910.305 G01 IV

Serious Gravity 1 1 instance 5 exposed
Issued
Feb 3, 2017
Penalty
Initial $3,531 · Current $2,118 Reduced
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv)(a):     Flexible extension cord(s) for a scale in the Acid building were wrapped around conduit and attached with zip strips.
Recent events (2)
  • — I (S) $2118
  • — Z (S) $3531

1910.1026 C

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 3, 2017
Abate by
Jun 16, 2017
Penalty
Initial $6,926 · Current $4,155 Reduced

Hazardous substances 0689

29 CFR 1910.1026(c): Employees were exposed to an airborne concentration of chromium (VI) which exceeded 5 micrograms per cubic meter of air, as an 8-hour time-weighted average:    The employer did not ensure that employee exposure to hexavalent chromium did not exceed 5 micrograms per cubic meter (ug/m3), as an 8 hour time weighted average (TWA). This violation occurred on or about September 28, 2016 in the welding/fabrication shop when stainless steel welding exposed an employee to hexavalent chromium at an 8 hour TWA of 13.6 ug/m3, approximately 2.7 time the PEL of 5.0 ug/m3. Sampling was performed for 385 minutes and zero exposure was assumed for the 95 minutes not sampled.
Recent events (2)
  • — I (S) $4155
  • — Z (S) $6926

1910.1026 F01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 3, 2017
Abate by
Jun 16, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 0689

29 CFR 1910.1026(f)(1)(i): Feasible engineering controls and work practices were not instituted to reduce and maintain employee exposures to chromium (VI) at or below the permissible exposure limit:    The employer did not ensure that engineering controls, such as exhaust ventilation, and work practices lowered employee exposure to hexavalent chromium below 5 micrograms per cubic meter (ug/m3), as an 8 hour time weighted average (TWA). This violation occurred on or about September 28, 2016 in the welding/fabrication shop when stainless steel welding exposed an employee to hexavalent chromium at an 8 hour TWA of 13.6 ug/m3, approximately 2.7 times the PEL of 5.0 ug/m3. Sampling was performed for 385 minutes and zero exposure was assumed for the 95 minutes not sampled.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1026 D02 I

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 3, 2017
Abate by
Jun 16, 2017
Penalty
Initial $6,926 · Current $4,155 Reduced

Hazardous substances 0689

29 CFR 1910.1026(d)(2)(i): The employer did not perform initial monitoring to determine the 8-hour time-weighted average exposure to chromium (VI) for each employee on the basis of a sufficient number of personal breathing zone air samples to accurately characterize full shift exposure on each shift, for each job classification, in each work area:    The employer did not ensure that employee(s) in the weld/fabrication shop, exposed to hexavalent chromium from welding or other hot work on chromium containing steel, were properly monitored to determine their 8-hour time-weighted average exposure levels.
Recent events (2)
  • — I (S) $4155
  • — Z (S) $6926

1910.1026 L01 I

Serious Gravity 5 4 instances 4 exposed
Issued
Feb 3, 2017
Abate by
Mar 23, 2017
Penalty
Initial $5,542 · Current $3,325 Reduced

Hazardous substances 0689

29 CFR 1910.1026(l)(2)(i): The employer did not ensure that all employees who were assigned to workplaces where there was exposure to chromium (VI) were provided with information and training as required by the Hazard Communication standard, 29 CFR 1910.1200:     The employer did not ensure that employee(s) in the weld/fabrication shop, exposed to hexavalent chromium from welding or other hot work on chromium containing steel, were properly were properly trained on the hazards, health effects, and the contents of this section.
Recent events (2)
  • — I (S) $3325
  • — Z (S) $5542

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341709798.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.