Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COLAIANNI CONSTRUCTION INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of COLAIANNI CONSTRUCTION INC. in CABIN DRIVE, MOUNDSVILLE, WV 26041 (NAICS 236220). OSHA activity number 341711265.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Colaianni Construction INC. — free Get an email when a new federal OSHA severe-injury report for Colaianni Construction INC. is published. One employer, no account, unsubscribe in one click.
Site address
CABIN DRIVE
City
MOUNDSVILLE
State
WV
ZIP
26041
Mailing
2141 STATE ROUTE 150, DILLONVALE, OH 43917
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
11
Ownership type
A

3 citations on file for this inspection.

1926.501 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 15, 2016
Penalty
Initial $6,235 · Current $4,365 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:    (a)  Tree House Cabin #4:  On August 18, 2016 and times prior, an employee was exposed to a fall hazard of approximately 32 feet to the ground below while working on the back deck of the cabin.  The deck was not equipped with a guardrail system or safety net and no personal fall arrest system was in place.
Recent events (2)
  • — I (S) $4364.5
  • — Z (S) $6235

1926.701 B

Serious Gravity 1 1 instance 4 exposed
Issued
Sep 15, 2016
Penalty
Initial $3,180 · Current $2,226 Reduced
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement:    (a)  Tree House Cabin #4:  On August 18, 2016 and times prior, there was 5 pieces of protruding rebar that ran along the walkway to the cabin that was not protected to prevent employee impalement and/or injury.
Recent events (2)
  • — I (S) $2226
  • — Z (S) $3180

1926.403 B01

Other-than-serious 1 instance 1 exposed
Issued
Sep 15, 2016
Abate by
Oct 4, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees:  (a)  Tree House Cabin #2:  On August 18, 2016 and times prior, employees operated a DeWalt miter saw (serial #56868, model #DW708) that had damage to the outer insulation of the power cord.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Colaianni Construction INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341711265.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.