MOBILE, AL —
OSHA Inspection: H. H. JORDAN CONSTRUCTION COMPANY, INC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of H. H. JORDAN CONSTRUCTION COMPANY, INC. in 1600 YEEND ST, MOBILE, AL 36603 (NAICS 236220). OSHA activity number 341719086.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- H. H. JORDAN CONSTRUCTION COMPANY, INC.
- Site address
- 1600 YEEND ST
- City
- MOBILE
- State
- AL
- ZIP
- 36603
- Mailing
- 3221 ANTON STREET, MOBILE, AL 36601
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 30
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.501 B01
- Issued
- Feb 14, 2017
- Abate by
- Feb 27, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) At Pump House Location: On or about August 22, 2016 and at times prior; the employer failed to ensure employees walking on a support beam had fall protection while attaching the cranes sling to the I-Beam exposing his employees to a fall hazard of 15 feet 1 inch to the ground and exposed rebar below.
Recent events (1)
- — Z (S) $0
1926.502 B01
- Issued
- Feb 14, 2017
- Abate by
- Feb 27, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(b)(1): The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level: a) At Pump House Location: On or about August 22, 2016 and at times prior; the employer failed to ensure the coffer dam walls located around the pump house being used as guardrails were the proper height of 42 inches as per the standard exposing his employees to a fall hazard of 18 feet to the ground below. The height of the wall was measured at 35 inches.
Recent events (1)
- — Z (S) $0
1926.502 D05
- Issued
- Feb 14, 2017
- Abate by
- Feb 27, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(5): Snaphooks shall be sized to be compatible with the member to which they are connected to prevent unintentional disengagement of the snaphook by depression of the snaphook keeper by the connected member, or shall be a locking type snaphook designed and used to prevent disengagement of the snaphook by the contact of the snaphook keeper by the connected member: a) At Pump House Location: On or about August 22, 2016 and at times prior; the employer failed to provide his employees with adequate snap hooks on their lanyards that would properly connect to anchor points used by employees exposing his employees to a fall hazard of up to 18 feet to the ground below. Employees were setting their snaphook on the hole not allowing the snaphook to close and lock. This would allow the snap hook to be easily knocked off without the employees knowledge.
Recent events (1)
- — Z (S) $0
1926.502 D06 V
- Issued
- Feb 14, 2017
- Abate by
- Feb 27, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(6)(v): A snaphook not of the locking type was engaged (i) directly to webbing, rope or wire rope; (ii) to each other (iii) to a Dee-ring to which another snaphook or other connector is attached;(iv) to a horizontal lifeline; or (v) to any object which is incompatibly shaped or dimensioned in relation to the snaphook such that unintentional disengagement could occur by the connected object being able to depress the snaphook keeper and release itself. a) At Pump House Location: On or about August 22, 2016 and at times prior; the employer allowed his employees to set his snaphook from his Personal Fall Arrest System on the holes in the coffer damn walls which would not allow the snaphooks to lock and could easily detach from the wall exposing the employees to a fall hazard of up to 18 feet to the ground below. The holes cut into the coffer dam wall were not large enough for the employee to run their snaphook and to tie off back to itself.
Recent events (1)
- — Z (S) $0
1926.701 B
- Issued
- Feb 14, 2017
- Abate by
- Feb 27, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement: a) At Pump House Location: On or about August 22, 2016 and at times prior; the employer failed to guard exposed rebar below workers cutting out support beams exposing them to an impalement hazard. The site superintendent was standing on a I-beam when it broke away from the wall causing the superintendent to fall and he became impaled by the rebar.
Recent events (1)
- — Z (S) $0
1926.350 A09
- Issued
- Feb 14, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.350(a)(9): Compressed gas cylinders were not secured in an upright position at all times: a) At Pump House Location: On or about August 22, 2016 and at times prior; the employer failed to ensure oxygen and acetylene bottles were secured exposing his employees to struck-by hazards.
Recent events (1)
- — Z (O) $0
1910.1200 H03 IV
- Issued
- Feb 14, 2017
- Abate by
- Mar 13, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(3)(iv): The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information: a) At H.H. Jordan Construction: On or about August 22, 2016 and at times prior; the employer exposed employees to chemical hazards to include but not limited to diesel fuel, oxygen and acetylene in that employees were not provided the new information and training on the UN Global Harmonized System (GHS) to include Safety Data Sheets (SDS).
Recent events (1)
- — Z (O) $0
More inspections at H. H. Jordan Construction Company, INC.
View H. H. Jordan Construction Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341719086.