Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PROGRESSIVE WASTE SOLUTIONS OF TX, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PROGRESSIVE WASTE SOLUTIONS OF TX, INC. in 15711 CAMERON ROAD, PFLUGERVILLE, TX 78660 (NAICS 562111). OSHA activity number 341723195.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Progressive Waste Solutions of TX, INC. — free Get an email when a new federal OSHA severe-injury report for Progressive Waste Solutions of TX, INC. is published. One employer, no account, unsubscribe in one click.
Site address
15711 CAMERON ROAD
City
PFLUGERVILLE
State
TX
ZIP
78660
Mailing
15711 CAMERON ROAD, PFLUGERVILLE, TX 78660
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562111
Employees
78
Ownership type
A

5 citations on file for this inspection.

1910.253 B04 III

Serious Gravity 5 1 instance 7 exposed
Issued
Aug 25, 2016
Penalty
Initial $7,126 · Current $4,276 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.  On or about 23 August 2016, and at times prior thereto, an Acetylene cylinder was sitting on the floor of the mechanic shop in close proximity to 5 Oxygen cylinders without a fire-resistance barrier or a distance of at least 20 foot separation, exposing employees in the shop to the hazard of a fire, explosion, or being struck by flying debris and projectiles.
Recent events (2)
  • — I (S) $4275.6
  • — Z (S) $7126

1910.253 B02 II

Serious Gravity 1 1 instance 7 exposed
Issued
Aug 25, 2016
Abate by
Aug 26, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders were not located where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons.  On or about 23 August 2016, and at times prior thereto, an Acetylene cylinder was sitting on the floor within the mechanic shop without being secured, while oxygen cylinders were stored within 7 feet away, exposing employees in the shop to a struck by hazard from the cylinder falling over.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 J02 IV

Serious Gravity 1 1 instance 14 exposed
Issued
Aug 25, 2016
Abate by
Aug 26, 2016
Penalty
Initial $5,345 · Current $3,207 Reduced
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location.  On or about 23 August 2016, and at times prior thereto, employees used two outlet receptacles located above a sink and within the kitchen/break room that were not ground-fault circuit-interrupter protected, exposing the employees to an electrical hazard of approximately 120 volts.
Recent events (2)
  • — I (S) $3207
  • — Z (S) $5345

1910.305 G01 IV B

Other-than-serious 1 instance 4 exposed
Issued
Aug 25, 2016
Abate by
Aug 26, 2016
Penalty
Initial $500 · Current $300 Reduced
29 CFR 1910.305(g)(1)(iv)(B): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used to run through holes in walls, ceilings, or floors.  On or about 23 August 2016, and at times prior thereto, a green extension cord ran through the ceiling of the office to provide power for various communication devices and equipment within the Men's bathroom, exposing employees using the bathroom to an electrical hazard of approximately 120 volts.
Recent events (2)
  • — I (O) $300
  • — Z (O) $500

1904.29 B01

Other-than-serious 1 instance 78 exposed
Issued
Aug 25, 2016
Abate by
Oct 7, 2016
Penalty
Initial $1,000 · Current $600 Reduced
29 CFR 1904.29(b)(1): A Log of all recordable work-related injuries and illnesses (OSHA Form 300 or equivalent) was not completed in the detail as required by the regulation.   At the inspection site, for calendar years 2012 through 2016, incomplete information for the cases on the Log materially impaired understandability of the nature of hazards, injuries and illnesses in the workplace in that either the type of injury was not recorded, the body part affected was not recorded, or the object/substance that directly injured or made the person ill was not recorded.
Recent events (2)
  • — I (O) $600
  • — Z (O) $1000

View Progressive Waste Solutions of TX, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341723195.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.