HOOKSETT, NH —
OSHA Inspection: D'ERAMO CONTRACTING LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of D'ERAMO CONTRACTING LLC in 35 CORRIVEAU DR., HOOKSETT, NH 03106 (NAICS 238160). OSHA activity number 341723336.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- D'ERAMO CONTRACTING LLC
- Site address
- 35 CORRIVEAU DR.
- City
- HOOKSETT
- State
- NH
- ZIP
- 03106
- Mailing
- 46 BEAN RD., MERRIMACK, NH 03054
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B10
- Issued
- Sep 7, 2016
- Penalty
- Initial $2,672 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: a. Site - Employees performing roofing work from a low slope roof were not protected from falls of approximately 10 feet when fall protection was not used or provided.
Recent events (2)
- — I (O) $0
- — Z (S) $2672
1926.1053 B01
- Issued
- Sep 7, 2016
- Penalty
- Initial $2,672 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. Site - Employees using a fiberglass extension ladder to gain access to and from the roof were not protected from falls of approximately 10 feet when the side rails of the ladder were only extended approximately 1 foot above the roofs eave.
Recent events (2)
- — I (O) $0
- — Z (S) $2672
More inspections in this industry (NAICS 238160)
More inspections in NH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341723336.