OSHA Inspection: VALCAR ROOFING GENERAL CONTRACTOR

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of VALCAR ROOFING GENERAL CONTRACTOR in 1229 WASHINGTON ST., EASTON, PA 18042 (NAICS 238160). OSHA activity number 341726990.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Valcar Roofing General Contractor — free Get an email when a new federal OSHA severe-injury report for Valcar Roofing General Contractor is published. One employer, no account, unsubscribe in one click.
Site address
1229 WASHINGTON ST.
City
EASTON
State
PA
ZIP
18042
Mailing
37 KENT ST., TRENTON, NJ 08611
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

2 citations on file for this inspection.

1926.1053 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 27, 2016
Penalty
Initial $2,672 · Current $1,672 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    a) 1221 Northampton St.  Easton, PA., Roof: On or about August 18, 2016, employees used an aluminum extension ladder to access a residential roof, approximately 18 feet above grade,  but the side rails did not extend at least 3 feet above the upper landing surface.
Recent events (2)
  • — I (S) $1672
  • — Z (S) $2672

1926.501 B13

Repeat Gravity 10 1 instance 5 exposed
Issued
Sep 27, 2016
Penalty
Initial $8,231 · Current $6,328 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):     a) 1221 Northampton St.  Easton, PA., Roof: On or about August 18, 2016, employees were performing residential roofing work, approximately between 18 to 25 feet above grade, without using any means of fall protection.        Valcar General Contractor, Inc. was previously cited for a violation of this occupational safety and health standard, 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1009343, citation number 1, item number 1 and was affirmed as a final order on December 29, 2016, with respect to a workplace located at 323 Windser Court, Macungie, PA;