CLEBURNE, TX —
OSHA Inspection: JOHNS MANVILLE
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of JOHNS MANVILLE in 200 WEST INDUSTRIAL BLVD., CLEBURNE, TX 76033 (NAICS 327993). OSHA activity number 341731297.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JOHNS MANVILLE
- Site address
- 200 WEST INDUSTRIAL BLVD.
- City
- CLEBURNE
- State
- TX
- ZIP
- 76033
- Mailing
- 200 WEST INDUSTRIAL BLVD., CLEBURNE, TX 76033
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327993
- Employees
- 400
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.22 A01
- Issued
- Feb 3, 2017
- Abate by
- Mar 6, 2017
- Penalty
- Initial $12,675 · Current $0 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms were not kept clean and orderly and in a sanitary condition. On the 91 HERM Meltor Level, the employer did not ensure that equipment and surrounding areas were kept clean of insulation exposing employees to struck-by, trip and fall hazards.
Recent events (3)
- — R (S) $0
- — C (S) $12675
- — Z (S) $12675
1910.23 C01
- Issued
- Feb 3, 2017
- Abate by
- Feb 19, 2018
- Penalty
- Initial $12,675 · Current $12,675
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard. Employees were exposed to fall hazards in the following areas: On August 25, 2016 on Unit 91 (HERM) employees were cleaning a drip pan while on a beam exposing them to a fall approximately 5 feet 10 inches from the top of the beam to the floor below."
Recent events (3)
- — R (S) $12675
- — C (S) $12675
- — Z (S) $12675
1910.212 A01
- Issued
- Feb 3, 2017
- Abate by
- Feb 19, 2018
- Penalty
- Initial $12,675 · Current $12,675
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. On the Collection Level, guardrails were removed when the line was down, potentially exposing employees to hazards. Employees also opened doors/panels to clean and remove product that had accumulated during operation. Equipment was stopped but not locked out while using designated tools to perform routine cleaning. Additional machine guarding methods were not in place to prevent employees from being potentially exposed to moving rollers, conveyers, shafts and other moving parts.
Recent events (3)
- — R (S) $12675
- — C (S) $12675
- — Z (S) $12675
1910.242 B
- Issued
- Feb 3, 2017
- Abate by
- Feb 19, 2018
- Penalty
- Initial $9,959 · Current $9,959
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i. On the Fiberizer Level, the employer failed to ensure the company's compressed air line was reduced to 30 p.s.i. for cleaning, exposing employees to air embolisms and struck-by hazards.
Recent events (3)
- — R (O) $9959
- — C (S) $9959
- — Z (S) $9959
1910.303 E02
- Issued
- Feb 3, 2017
- Abate by
- Feb 19, 2018
- Penalty
- Initial $9,959 · Current $9,959
General-duty citation text
29 CFR 1910.303(e)(2): Durability. The marking was not of sufficient durability to withstand the environment involved. On the collection level, there were electrical disconnects that had illegal labels.
Recent events (3)
- — R (O) $9959
- — C (S) $9959
- — Z (S) $9959
More inspections at Johns Manville
View Johns Manville's full OSHA safety record →
More inspections in this industry (NAICS 327993)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341731297.