CHESAPEAKE, VA —
OSHA Inspection: PRISM MARITIME LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PRISM MARITIME LLC in 1416 KELLAND DRIVE SUITE B, CHESAPEAKE, VA 23320 (NAICS 336611). OSHA activity number 341731875.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PRISM MARITIME LLC
- Site address
- 1416 KELLAND DRIVE SUITE B
- City
- CHESAPEAKE
- State
- VA
- ZIP
- 23320
- Mailing
- 1416 KELLAND DRIVE SUITE B, CHESAPEAKE, VA 23320
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336611
- Employees
- 122
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.305 G01 IV A
- Issued
- Sep 23, 2016
- Penalty
- Initial $4,089 · Current $4,089
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Weld/Test Lab: On or about 08/17/2016, the employer had two orange extension cords used in lieu of permanent wiring plugged into duplex receptacles that supplied power to fans mounted in the ceiling. b) Warehouse office: On or about 08/17/2016, the employer had an orange extension cord used in lieu of permanent wiring plugged into a duplex receptacle that supplied power to an air condition unit recessed into a wall. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $4089
1910.1025 D02
- Issued
- Sep 23, 2016
- Abate by
- Oct 28, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1025(d)(2): An initial determination was not made to determine if any employee may be exposed to lead at or above the action level: a) USS Wasp LHD1, Compartment 1-123-6-Q: On or about 06/6/2016, an employee used a needle gun to removed paint from the internal surfaces of a vessel that was known to have a lead content up to 0.050 percent. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (O) $0
1915.1026 D01
- Issued
- Sep 23, 2016
- Abate by
- Oct 28, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1915.1026(d)(1): The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI): a) USS Wasp LHD1, Compartment 1-123-6-Q: On or about 06/6/2016, an employee used a needle gun to removed paint from the internal surfaces of a vessel that was known to have a chromium content up to 0.02 percent. Note: The employer is to make this determination in accordance with either paragraph (d)(2), the scheduled monitoring option, or paragraph (d)(3), the performance-oriented option. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (O) $0
More inspections at Prism Maritime LLC
View Prism Maritime LLC's full OSHA safety record →
More inspections in this industry (NAICS 336611)
More inspections in VA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341731875.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.