Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MEKIS CONSTRUCTION CORPORATION

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of MEKIS CONSTRUCTION CORPORATION in BRIDGE AT ROUTE 322 AND ROUTE 427, FRANKLIN, PA 16323 (NAICS 237310). OSHA activity number 341736429.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mekis Construction Corporation — free Get an email when a new federal OSHA severe-injury report for Mekis Construction Corporation is published. One employer, no account, unsubscribe in one click.
Site address
BRIDGE AT ROUTE 322 AND ROUTE 427
City
FRANKLIN
State
PA
ZIP
16323
Mailing
1595 ROUTE 422 EAST, FENELTON, PA 16034
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237310
Employees
24
Ownership type
A

5 citations on file for this inspection.

1926.404 B01 I

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 5, 2017
Abate by
Feb 1, 2017
Penalty
Initial $4,240 · Current $3,452 Reduced
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites:    a.) Mekis Construction Corporation/Construction Site/Bridge Project Near Route 322 & Route 427  --- East Side Abutment Area/Carpentry Operations: On or about July 8, 2016, extension cords were utilized to power a handheld DeWalt Circular saw.  GFCIs and/or assured equipment grounding program were not utilized to protect the extension cords and circular saw.
Recent events (2)
  • — I (S) $3452
  • — Z (S) $4240

1926.403 B01 II

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 5, 2017
Abate by
Feb 1, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.403(b)(1)(ii): Mechanical strength and durability was not maintained for parts designed to enclose and protect electrical equipment:  a.) Mekis Construction Corporation/Construction Site/Bridge Project Near Route 322 & Route 427  --- East Side Abutment Area/Carpentry Operations: On or about July 8, 2016, an extension cord with twist lock style connectors was utilized to power extension cords and a handheld DeWalt Circular saw.  A protective cap on the end of one of the connectors was missing.  The condition exposed the area where the extension cord's internal conductors entered the twist lock connector.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.405 G02 IV

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 5, 2017
Abate by
Feb 1, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:   a.) Mekis Construction Corporation/Construction Site/Bridge Project Near Route 322 & Route 427  --- East Side Abutment Area/Carpentry Operations: On or about July 8, 2016, an extension cord with twist lock style connectors was utilized to power extension cords and a handheld DeWalt Circular saw.  A section of the extension cord was not outfitted with a strain relief mechanism due to a protective cap that was missing from the end of one of the twist lock connectors.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.350 A10

Other-than-serious 2 instances 10 exposed
Issued
Jan 5, 2017
Abate by
Feb 1, 2017
Penalty
Initial $3,180 · Current $1,000 Reduced
29 CFR 1926.350(a)(10): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire resistance rating:    a.) Mekis Construction Corporation/Construction Site/Bridge Project Near Route 322 & Route 427  --- East Side Access Road Area: On or about July 8, 2016, 2 propane cylinders and 2 oxygen cylinders were stored directly next to one another.
Recent events (2)
  • — I (O) $1000
  • — Z (S) $3180

1926.1052 C04

Other-than-serious 3 instances 24 exposed
Issued
Jan 5, 2017
Abate by
Feb 1, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.1052(c)(4): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members were not provided between the top rail of the stairrail system and the stairway steps:       a.) Mekis Construction Corporation/Construction Site/Bridge Project Near Route 322 & Route 427  --- Stairways for the job site Storage Trailers: On or about July 8, 2016, the tractor trailer style storage trailers were equipped with stairways at the rear section of the trailers.  The stairway's stairrail systems were not equipped with mid-rails or equivalent intermediate members.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Mekis Construction Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341736429.