FRANKLIN, PA —
OSHA Inspection: MEKIS CONSTRUCTION CORPORATION
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of MEKIS CONSTRUCTION CORPORATION in BRIDGE AT ROUTE 322 AND ROUTE 427, FRANKLIN, PA 16323 (NAICS 237310). OSHA activity number 341736429.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MEKIS CONSTRUCTION CORPORATION
- Site address
- BRIDGE AT ROUTE 322 AND ROUTE 427
- City
- FRANKLIN
- State
- PA
- ZIP
- 16323
- Mailing
- 1595 ROUTE 422 EAST, FENELTON, PA 16034
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237310
- Employees
- 24
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.404 B01 I
- Issued
- Jan 5, 2017
- Abate by
- Feb 1, 2017
- Penalty
- Initial $4,240 · Current $3,452 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: a.) Mekis Construction Corporation/Construction Site/Bridge Project Near Route 322 & Route 427 --- East Side Abutment Area/Carpentry Operations: On or about July 8, 2016, extension cords were utilized to power a handheld DeWalt Circular saw. GFCIs and/or assured equipment grounding program were not utilized to protect the extension cords and circular saw.
Recent events (2)
- — I (S) $3452
- — Z (S) $4240
1926.403 B01 II
- Issued
- Jan 5, 2017
- Abate by
- Feb 1, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(b)(1)(ii): Mechanical strength and durability was not maintained for parts designed to enclose and protect electrical equipment: a.) Mekis Construction Corporation/Construction Site/Bridge Project Near Route 322 & Route 427 --- East Side Abutment Area/Carpentry Operations: On or about July 8, 2016, an extension cord with twist lock style connectors was utilized to power extension cords and a handheld DeWalt Circular saw. A protective cap on the end of one of the connectors was missing. The condition exposed the area where the extension cord's internal conductors entered the twist lock connector.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.405 G02 IV
- Issued
- Jan 5, 2017
- Abate by
- Feb 1, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a.) Mekis Construction Corporation/Construction Site/Bridge Project Near Route 322 & Route 427 --- East Side Abutment Area/Carpentry Operations: On or about July 8, 2016, an extension cord with twist lock style connectors was utilized to power extension cords and a handheld DeWalt Circular saw. A section of the extension cord was not outfitted with a strain relief mechanism due to a protective cap that was missing from the end of one of the twist lock connectors.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.350 A10
- Issued
- Jan 5, 2017
- Abate by
- Feb 1, 2017
- Penalty
- Initial $3,180 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.350(a)(10): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire resistance rating: a.) Mekis Construction Corporation/Construction Site/Bridge Project Near Route 322 & Route 427 --- East Side Access Road Area: On or about July 8, 2016, 2 propane cylinders and 2 oxygen cylinders were stored directly next to one another.
Recent events (2)
- — I (O) $1000
- — Z (S) $3180
1926.1052 C04
- Issued
- Jan 5, 2017
- Abate by
- Feb 1, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(4): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members were not provided between the top rail of the stairrail system and the stairway steps: a.) Mekis Construction Corporation/Construction Site/Bridge Project Near Route 322 & Route 427 --- Stairways for the job site Storage Trailers: On or about July 8, 2016, the tractor trailer style storage trailers were equipped with stairways at the rear section of the trailers. The stairway's stairrail systems were not equipped with mid-rails or equivalent intermediate members.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Mekis Construction Corporation
View Mekis Construction Corporation's full OSHA safety record →
More inspections in this industry (NAICS 237310)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341736429.