TAMPA, FL —
OSHA Inspection: BOB'S BARRICADES
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BOB'S BARRICADES in 5018 24TH AVE. S., TAMPA, FL 33619 (NAICS 332999). OSHA activity number 341738920.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BOB'S BARRICADES
- Site address
- 5018 24TH AVE. S.
- City
- TAMPA
- State
- FL
- ZIP
- 33619
- Mailing
- 5018 24TH AVE. S., TAMPA, FL 33619
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 12
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.36 D01
- Issued
- Oct 14, 2016
- Penalty
- Initial $2,433 · Current $1,460 Reduced
General-duty citation text
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: (a) In the shop the back exit door was locked, on or about 9/16/2016.
Recent events (2)
- — I (S) $1459.8
- — Z (S) $2433
1910.215 A01
- Issued
- Oct 14, 2016
- Penalty
- Initial $2,433 · Current $1,460 Reduced
General-duty citation text
29 CFR 1910.215(a)(1): Abrasive wheel(s) used on grinding machinery were not used with safety guard(s): (a) In the light repair shop, the Delta Grinder was not guarded, on or about 9/16/2016.
Recent events (2)
- — I (S) $1459.8
- — Z (S) $2433
1910.178 A03
- Issued
- Oct 14, 2016
- Abate by
- Nov 25, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(a)(3): Approved trucks did not bear a label or some other identifying mark indicating approval by the testing laboratory. (a) In the shop, the Hyundai forklift did not have a face plate indicating the load capacity, on or about 9/16/2016.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 F06
- Issued
- Oct 14, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(6): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information specified under paragraphs (f)(6)(i) through (ii) of this section: (a) In the shop, a container of DEF (diesel exhaust fluid) solution was not labeled, on or about 9/16/2016.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Bob'S Barricades
View Bob'S Barricades's full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341738920.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.