JACKSONVILLE, NC —
OSHA Inspection: RUSH MASONRY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RUSH MASONRY in CAMP LEJEUNE, JACKSONVILLE, NC 28540 (NAICS 238140). OSHA activity number 341743581.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RUSH MASONRY
- Site address
- CAMP LEJEUNE
- City
- JACKSONVILLE
- State
- NC
- ZIP
- 28540
- Mailing
- 234 CLAYTON JAMES ROAD, JACKSONVILLE, NC 28540
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 25
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.451 G04 VII
- Issued
- Sep 28, 2016
- Abate by
- Oct 18, 2016
- Penalty
- Initial $2,352 · Current $1,411 Reduced
General-duty citation text
29 CFR 1926.451(g)(4)(vii): Each toprail or equivalent member of a guardrail system was not capable of withstanding, without failure, a force applied in any downward or horizontal direction at any point along its top edge of at least 100 pounds (445 n) or guardrail systems installed on single-point adjustable suspension scaffolds or two-point adjustable suspension scaffolds, and at least 200 pounds (890 n) for guardrail systems installed on all other scaffolds. New River Air Station, Maintenance Training Facility: Scaffold guardrail system was not adequately secured with a double wrap wire connection. Single wrap wire tensile strength did not provide support for 200 Lbs in any outward or downward direction. Wire were not twisted to a minimum of 5 wraps to ensure the ultimate strength.
Recent events (2)
- — I (S) $1411.2
- — Z (S) $2352
1926.451 G04 IX
- Issued
- Sep 28, 2016
- Abate by
- Oct 18, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(4)(ix): Midrails, screens, mesh, intermediate vertical members, soild panels, and equivalent structural members of a guardrail system were not capable of withstanding, without failure, a force to applied in any downward or horizontal direction at any point along the midrail or other member of at least 75 pounds for guardrail systems with a minimum 100 pound toprail capacity, and at least 150 pounds for guardrail systems with a minimum 200 pound toprail capacity: New River Air Station, Maintenance Training Facility: Scaffold guardrail system was not adequately secured with a double wrap wire connection. Single wrap wire tensile strength did not provide support for 200 Lbs in any outward or downward direction. Wire connections were not twisted to a minimum of 5 wraps to ensure the ultimate strength.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Rush Masonry
View Rush Masonry's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in NC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341743581.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.