LAKEWOOD, CO —
OSHA Inspection: AC EXTERIORS, LLC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AC EXTERIORS, LLC. in 14930 W. EVANS PL., LAKEWOOD, CO 80226 (NAICS 238160). OSHA activity number 341744142.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AC EXTERIORS, LLC.
- Site address
- 14930 W. EVANS PL.
- City
- LAKEWOOD
- State
- CO
- ZIP
- 80226
- Mailing
- 3654 DECATUR ST, DENVER, CO 80221
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Sep 12, 2016
- Abate by
- Oct 6, 2016
- Penalty
- Initial $3,741 · Current $3,741
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system: (a) On or about August 20, 2016, AC Exteriors, LLC., did not ensure that its employees were protected from falls while working at heights greater than 6 feet. Employees of AC Exteriors, LLC. were exposed to fall hazards in excess of 23 feet while engaged in roofing activities on a two- story residential building with no fall protection in place. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $3741
1926.1053 B01
- Issued
- Sep 12, 2016
- Abate by
- Oct 6, 2016
- Penalty
- Initial $2,672 · Current $2,672
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to upper landing surfaces, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladders were used to gain access: (a) On or about August 20, 2016, AC Exteriors, LLC. did not ensure that portable ladders, used to access upper landing surfaces, extend at least 3 feet above the upper landing surface to which the ladders were used to gain access. Workers were observed using a ladder to access the roof of a residential building. Ladder did not extend at least 3 ft above the landing platform exposing employees to falls of up to 8 feet. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $2672
More inspections at AC Exteriors, LLC.
View AC Exteriors, LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341744142.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.