Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. PAPER CONVERTERS, INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of U.S. PAPER CONVERTERS, INC in 4808 CONVERTERS AVE, APPLETON, WI 54915 (NAICS 322299). OSHA activity number 341746592.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Paper Converters, INC — free Get an email when a new federal OSHA severe-injury report for U.S. Paper Converters, INC is published. One employer, no account, unsubscribe in one click.
Site address
4808 CONVERTERS AVE
City
APPLETON
State
WI
ZIP
54915
Mailing
4808 CONVERTERS AVE, APPLETON, WI 54915
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322299
Employees
61
Ownership type
A

2 citations on file for this inspection.

1910.176 B

Repeat 20 instances 6 exposed
Issued
Sep 19, 2016
Abate by
Oct 3, 2016
Penalty
Initial $2,744 · Current $1,509 Reduced
29 CFR 1910.176(b): Storage of material created a hazard:    a) On or about September 12, 2016 in the Baling Department; the paper roll stubs were not stored in a manner which would prevent them from tipping over, exposing employees to struck-by hazards.    U.S. Paper Converters, Inc. was previously cited for a violation of an equivalent Occupational Safety and Health Standard 1910.176(b), which was contained in OSHA inspection number 1081262, citation number 2, item number 1 and was affirmed as a final order on September 19, 2015, with respect to a workplace located at 4808 Converters Ave. Appleton, WI 54915.
Recent events (2)
  • — I (R) $1509.2
  • — Z (R) $2744

1910.303 C03 I

Other-than-serious 1 instance 6 exposed
Issued
Sep 19, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.303(c)(3)(i): All splices and joints and the free ends of the conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose:  a) On or about September 2, 2016 the flexible cord powering the scale near the baler had been repaired with black electrical tape and not an equivalent insulator as the cord sheathing.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View U.S. Paper Converters, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341746592.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.