Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NESTLE USA, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NESTLE USA, INC. in 216 N. MORTON AVE., MORTON, IL 61550 (NAICS 311421). OSHA activity number 341746808.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nestle USA, INC. — free Get an email when a new federal OSHA severe-injury report for Nestle USA, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
NESTLE USA, INC.
Site address
216 N. MORTON AVE.
City
MORTON
State
IL
ZIP
61550
Mailing
P.O. BOX 198, MORTON, IL 61550
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311421
Employees
190
Ownership type
A

3 citations on file for this inspection.

1910.147 D

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Nov 16, 2016
Abate by
Dec 9, 2016
Penalty
Initial $12,471 · Current $0 Reduced
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):    On or about August 13, 2016, employees cleaning the sensors on the palletizer were exposed to caught-in and amputation hazards from the piston and diverter arm, because the employer considered emergency stops as safe guarding equipment.  Employees who performed servicing and maintenance on the palletizers were not required to turned off or shut down, using the procedures established for the machine or equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $12471

1910.147 F01 II

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Nov 16, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(f)(1)(ii): When lockout or tagout devices temporarily were removed from the energy isolating device and the machine or equipment was energized to test or position the machine, the employees were not removed from the machine or equipment area in accordance to the paragraph (e)(2):     On or about August 13, 2016, an employee was exposed to caught-in and amputation hazards when testing or positioning the palletizer because the employee did not check all employees have been safely positioned or removed from the infeed conveyor belt.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 II

Other-than-serious 1 instance 4 exposed
Issued
Nov 16, 2016
Abate by
Dec 9, 2016
Penalty
Initial $1,000 · Current $1,000
29 CFR 1910.147(c)(6)(ii): The periodic inspection certification of energy control procedures did not contain the required documentation on identification of the machine or equipment, inspection date, employees included, and the person performing the inspection      On or about August 25, 2016, Nestle USA, Inc. located in Morton, Illinois, did not document periodic inspections for energy isolation and record the identification of the machine or equipment, inspection date, names of the employees included in the inspection and the name of the person performing the inspection.
Recent events (2)
  • — I (O) $1000
  • — Z (O) $1000

View Nestle USA, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341746808.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.