MCALLEN, TX —
OSHA Inspection: RIO ROOFING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RIO ROOFING, INC. in 612 EXPRESSWAY 83, MCALLEN, TX 78501 (NAICS 238160). OSHA activity number 341756302.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RIO ROOFING, INC.
- Site address
- 612 EXPRESSWAY 83
- City
- MCALLEN
- State
- TX
- ZIP
- 78501
- Mailing
- 310 HANMORE INDUSTRIAL PARKWAY, HARLINGEN, TX 78550
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B01
- Issued
- Feb 24, 2017
- Penalty
- Initial $4,183 · Current $2,510 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. At this jobsite, employees conducting roofing work on a commercial building, without fall protection, were exposed to fall hazards greater than 6 feet above ground.
Recent events (2)
- — I (S) $2509.8
- — Z (S) $4183
1926.1053 B01
- Issued
- Feb 24, 2017
- Penalty
- Initial $2,988 · Current $1,793 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. At a commercial building under renovation, a 10 foot A-frame ladder was used, to gain access to the working level, did not extend at least 3 feet above the landing. This exposed employees to a fall hazard of greater than 6 feet.
Recent events (2)
- — I (S) $1792.8
- — Z (S) $2988
1926.1053 B04
- Issued
- Feb 24, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: At a commercial building under renovation, a 10 foot A-frame ladder was used, to gain access to the working level, was not used in accordance with the manufacture's design. This exposed employees to a fall hazard of greater than 6 feet.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at RIO Roofing, INC.