Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PRISM ELECTRIC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of PRISM ELECTRIC in TERMINAL A GATE 39, DFW AIRPORT, TX 75261 (NAICS 238210). OSHA activity number 341760163.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Prism Electric — free Get an email when a new federal OSHA severe-injury report for Prism Electric is published. One employer, no account, unsubscribe in one click.
Establishment
PRISM ELECTRIC
Site address
TERMINAL A GATE 39
City
DFW AIRPORT
State
TX
ZIP
75261
Mailing
2985 MARKET ST, GARLAND, TX 75041
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
100
Ownership type
A

1 citation on file for this inspection.

1926.502 B03

Other-than-serious 1 instance 3 exposed
Issued
Jan 19, 2017
Abate by
Feb 9, 2017
Penalty
Initial $6,338 · Current $6,338
29 CFR 1926.502(b)(3): Guardrail systems were not capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied within 2 inches (5.1 cm) of the top edge, in any outward or downward direction, at any point along the top edge:    In Terminal A, Gate 39, third floor:  The employer did not ensure employees working on or around an elevator shaft were protected from a fall hazard such as but not limited to when the guardrails were not installed correctly or while being repaired.  Employees were exposed to an unprotected fall hazard of approximately 30 feet to the concrete below.