OSHA Inspection: WORLEY PARSONS

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WORLEY PARSONS in 8580 SHELDON ROAD, HOUSTON, TX 77049 (NAICS 541330). OSHA activity number 341760262.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Worley Parsons — free Get an email when a new federal OSHA severe-injury report for Worley Parsons is published. One employer, no account, unsubscribe in one click.
Establishment
WORLEY PARSONS
Site address
8580 SHELDON ROAD
City
HOUSTON
State
TX
ZIP
77049
Mailing
8580 SHELDON ROAD, HOUSTON, TX 77049
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541330
Employees
27
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 II D

Other-than-serious 1 instance 4 exposed
Issued
Nov 9, 2016
Abate by
Nov 30, 2016
Penalty
Initial $12,471 · Current $12,471
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures.     On or about September 06, 2016, and at times prior thereto, employees working in Unit #3 were exposed to thermal burn and struck-by hazards, while working, servicing and cleaning Unit #3 without specific requirements for testing the Unit to determine and verify the effectiveness of the energy control procedure.
Recent events (2)
  • — I (O) $12471
  • — Z (S) $12471

1910.147 D05 II

Other-than-serious 1 instance 4 exposed
Issued
Nov 9, 2016
Abate by
Nov 30, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(5)(ii): Where there was a possibility of re-accumulation of stored energy to a hazardous level, verification of isolation was not continued until the servicing or maintenance was completed, or until the possibility of such accumulation no longer exist.    On or about September 06, 2016, and at times prior thereto, employees working in Unit #3 were exposed to thermal burn and struck-by hazards, while working, servicing and cleaning a boiler with the possibility of re-accumulation of stored energy to a hazardous level without a continued verification of the isolation or until the possibility of such accumulation no longer exist.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.147 C06 I

Other-than-serious 1 instance 4 exposed
Issued
Nov 9, 2016
Abate by
Nov 30, 2016
Penalty
Initial $12,471 · Current $12,471
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed.    On or about September 06, 2016, and at times prior thereto, employees working in Unit #3 were exposed to thermal burn and struck-by hazards, while working, servicing and cleaning Unit #3 without the employer having conducted a periodic inspection of the energy control procedure at least annually.
Recent events (2)
  • — I (O) $12471
  • — Z (S) $12471

1910.147 D03

Other-than-serious 1 instance 4 exposed
Issued
Nov 9, 2016
Abate by
Nov 30, 2016
Penalty
Initial $12,471 · Current $12,471
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s).     On or about September 06, 2016, and at times prior thereto, employees working in unit #3 were exposed to thermal burn and struck-by hazards while working, servicing and cleaning Unit #3 without all energy isolating devices needed to control energy in the unit were physically located and operated in a manner to the isolate the equipment from energy sources.
Recent events (2)
  • — I (O) $12471
  • — Z (S) $12471