HOUSTON, TX —
OSHA Inspection: WORLEY PARSONS
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of WORLEY PARSONS in 8580 SHELDON ROAD, HOUSTON, TX 77049 (NAICS 541330). OSHA activity number 341760262.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WORLEY PARSONS
- Site address
- 8580 SHELDON ROAD
- City
- HOUSTON
- State
- TX
- ZIP
- 77049
- Mailing
- 8580 SHELDON ROAD, HOUSTON, TX 77049
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 541330
- Employees
- 27
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 II D
- Issued
- Nov 9, 2016
- Abate by
- Nov 30, 2016
- Penalty
- Initial $12,471 · Current $12,471
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures. On or about September 06, 2016, and at times prior thereto, employees working in Unit #3 were exposed to thermal burn and struck-by hazards, while working, servicing and cleaning Unit #3 without specific requirements for testing the Unit to determine and verify the effectiveness of the energy control procedure.
Recent events (2)
- — I (O) $12471
- — Z (S) $12471
1910.147 D05 II
- Issued
- Nov 9, 2016
- Abate by
- Nov 30, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(5)(ii): Where there was a possibility of re-accumulation of stored energy to a hazardous level, verification of isolation was not continued until the servicing or maintenance was completed, or until the possibility of such accumulation no longer exist. On or about September 06, 2016, and at times prior thereto, employees working in Unit #3 were exposed to thermal burn and struck-by hazards, while working, servicing and cleaning a boiler with the possibility of re-accumulation of stored energy to a hazardous level without a continued verification of the isolation or until the possibility of such accumulation no longer exist.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- Nov 9, 2016
- Abate by
- Nov 30, 2016
- Penalty
- Initial $12,471 · Current $12,471
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed. On or about September 06, 2016, and at times prior thereto, employees working in Unit #3 were exposed to thermal burn and struck-by hazards, while working, servicing and cleaning Unit #3 without the employer having conducted a periodic inspection of the energy control procedure at least annually.
Recent events (2)
- — I (O) $12471
- — Z (S) $12471
1910.147 D03
- Issued
- Nov 9, 2016
- Abate by
- Nov 30, 2016
- Penalty
- Initial $12,471 · Current $12,471
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s). On or about September 06, 2016, and at times prior thereto, employees working in unit #3 were exposed to thermal burn and struck-by hazards while working, servicing and cleaning Unit #3 without all energy isolating devices needed to control energy in the unit were physically located and operated in a manner to the isolate the equipment from energy sources.
Recent events (2)
- — I (O) $12471
- — Z (S) $12471
More inspections at Worley Parsons
View Worley Parsons's full OSHA safety record →
More inspections in this industry (NAICS 541330)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341760262.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.