Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: API INDUSTRIES, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of API INDUSTRIES, INC. in 2 GLENSHAW ST., ORANGEBURG, NY 10962 (NAICS 326111). OSHA activity number 341762136.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch API Industries, INC. — free Get an email when a new federal OSHA severe-injury report for API Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2 GLENSHAW ST.
City
ORANGEBURG
State
NY
ZIP
10962
Mailing
2 GLENSHAW ST., ORANGEBURG, NY 10962
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326111
Employees
400
Ownership type
A

4 citations on file for this inspection.

1910.132 A

Serious Gravity 10 1 instance 21 exposed
Issued
Feb 2, 2017
Abate by
Oct 17, 2017
Penalty
Initial $11,408 · Current $6,405 Reduced
29 CFR 1910.132(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact:    location: entire site   on or about: 8/11/16    a) Employees, starting up and maintaining extruder lines, were not using appropriate personal protective equipment.       NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (3)
  • — J (S) $6405
  • — C (S) $11408
  • — Z (S) $11408

1910.147 C04 I

Serious Gravity 10 1 instance 21 exposed
Issued
Feb 2, 2017
Abate by
Oct 17, 2017
Penalty
Initial $11,408 · Current $6,405 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    location: entire site   on or about: 8/11/16    a) Adequate procedures were not developed, documented and utilized for work including but not limited to changing extruder drives from DC to AC current.        NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (3)
  • — J (S) $6405
  • — C (S) $11408
  • — Z (S) $11408

1910.303 B01

Serious Gravity 10 1 instance 8 exposed
Issued
Feb 2, 2017
Penalty
Initial $11,408 · Current $6,405 Reduced
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:    location: heat control switch gear box, line 4  on or about: 8/20/16    a) The handle for the main power switch to the gear box was missing.       NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (3)
  • — J (S) $6405
  • — C (S) $11408
  • — Z (S) $11408

1910.303 G01 I A

Serious Gravity 1 2 instances 300 exposed
Issued
Feb 2, 2017
Penalty
Initial $4,889 · Current $2,785 Reduced
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910:    location: east basement  on or about: 8/11/16    a) The main electrical breakers were blocked by stored materials.      location: machine shop  on or about: 8/11/16    b) The main electrical breakers were blocked by stored materials.       NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (3)
  • — J (S) $2785
  • — C (S) $4889
  • — Z (S) $4889

View API Industries, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341762136.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.