OSHA Inspection: HARRIS-CAMDENTERMINAL EQUIPMENT

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of HARRIS-CAMDENTERMINAL EQUIPMENT in 2201 MT EPHRAIM AVENUE BUILDING 18, CAMDEN, NJ 08104 (NAICS 484121). OSHA activity number 341765766.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Harris-Camdenterminal Equipment — free Get an email when a new federal OSHA severe-injury report for Harris-Camdenterminal Equipment is published. One employer, no account, unsubscribe in one click.
Site address
2201 MT EPHRAIM AVENUE BUILDING 18
City
CAMDEN
State
NJ
ZIP
08104
Mailing
2201 MT EPHRAIM AVENUE BUILDING 18, CAMDEN, NJ 08104
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
484121
Employees
38
Ownership type
A

15 citations on file for this inspection.

1910.24 H

Serious Gravity 1 2 instances 2 exposed
Issued
Mar 1, 2017
Abate by
Apr 14, 2017
Penalty
Initial $3,802 · Current $2,281 Reduced
29 CFR 1910.24(h): Standard railings were not provided on the open sides of all exposed stairways and stair platforms:     a) Facility, Shop: The stairs leading to the overhead storage area were not provided with a mid-rail, on or about 9/12/2016.    b) Facility, Shop: The stairs leading to the file room were not provided with a standard stair rail system, on or about 9/12/2016.    NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $2281
  • — Z (S) $3802

1910.157 C01

Serious Gravity 1 4 instances 3 exposed
Issued
Mar 1, 2017
Abate by
Apr 14, 2017
Penalty
Initial $3,802 · Current $2,281 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:    a)  Building 18, Shop, Next to used oil tank: Two 10 pound fire extinguishers were blocked by a 55 gallon drum and plastic containers. The extinguishers were not mounted, on or about 9/12/2016.    b) Building 18, Shop, Next to Eyewash Station: One 10 pound portable fire extinguisher was blocked by miscellaneous stored items, on or about 9/12/2016.    c) Building 18, Shop, Next to Snap-On Tool Box: One 10 pound portable fire extinguisher was blocked by small miscellaneous metal parts, on or about 9/12/2016.    d) Building 18, Near Air Compressor: One  10 pound portable fire extinguisher was blocked by metal containers which were used to store metal chains and hooks, on or about 9/12/2016.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (2)
  • — I (S) $2281
  • — Z (S) $3802

1910.157 E02

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 1, 2017
Abate by
Apr 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:    a)  Building 18: Portable fire extinguishers were not inspected monthly, on or about 9/12/2016.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 G02

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 1, 2017
Abate by
Apr 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter:    a)  Facility: The employer failed to provide training on the use of portable fire extinguishers and the hazards associated with fighting incipient stage fires at least annually, on or about 9/12/2016.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L04 I

Serious Gravity 5 1 instance 9 exposed
Issued
Mar 1, 2017
Abate by
Apr 14, 2017
Penalty
Initial $5,070 · Current $3,042 Reduced
29 CFR 1910.178(l)(4)(i): Refresher training, including an evaluation of the effectiveness of that training, was not conducted as required by paragraph (l)(4)(ii) to ensure that the operator had the knowledge and skills needed to operate the powered industrial truck safely    a) Facility, Shop: Refresher training and an evaluation of the driver's performance was not conducted at least once every 3 years, on or about 9/12/2016.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (2)
  • — I (S) $3042
  • — Z (S) $5070

1910.212 A05

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 1, 2017
Abate by
Apr 14, 2017
Penalty
Initial $6,338 · Current $3,802 Reduced
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level:    a) Building 18, Shop, Overhead Storage Area: The fan located on the wall in the overhead storage area was not provided with a guard, 9/12/2016.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (2)
  • — I (S) $3802
  • — Z (S) $6338

1910.215 A04

Serious Gravity 5 2 instances 5 exposed
Issued
Mar 1, 2017
Abate by
Apr 14, 2017
Penalty
Initial $6,338 · Current $3,802 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:     a) Shop: The work rest on the Jet 10 inch bench grinder were adjusted to 1/4 of an inch away from the abrasive wheel, on or about 9/12/2016.     NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (2)
  • — I (S) $3802
  • — Z (S) $6338

1910.215 B09

Serious Gravity 5 2 instances 5 exposed
Issued
Mar 1, 2017
Abate by
Apr 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one-fourth inch:    a) Shop: Blue pedestal bench grinder was missing a tongue guard on the right side, the distance from the abrasive wheel to the safety guard peripheral member was measured at 2 1/2 inches, on or about 9/12/2016.    b) Shop: Jet 10 inch bench grinder was missing a tongue guard on the left side, the distance from the abrasive wheel to the safety guard peripheral member was measured at  1 1/2 inches, on or about 9/12/2016.     NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B02

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 1, 2017
Abate by
Apr 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:       a) Building 18, Shop: The plug which powers the blue pedestal bench grinder was plugged into an outlet that was not provided with a cover,  on or about 9/12/2016.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 E01

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Mar 1, 2017
Abate by
Mar 27, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(e)(1): Identification of manufacturer and ratings. Electric equipment may not be used unless the following markings have been placed on the equipment: voltage, current, wattage, manufacturer's name, trademark, or other descriptive marking by which the organization responsible for the product could be identified         a) Shop: The manufacturer's name, trademark, or other descriptive marking by which the organization responsible for the product was missing on the Blue pedestal bench grinder.  The bench grinder was also missing markings which included  the voltage, current, and wattage , on or about 9/12/2016.  NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 1, 2017
Abate by
Apr 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:        a) Building 18, Shop: The plug end of the equipment cord  which powers the blue pedestal bench grinder was lacking strain relief, on or about 9/12/2016.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01 VII B

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 1, 2017
Abate by
Apr 14, 2017
Penalty
Initial $6,338 · Current $3,802 Reduced
29 CFR 1910.303(g)(1)(vii)(B): The employer did not ensure that outdoor electrical equipment was protected from accidental contact by vehicular traffic.     a) Exterior of Building 18, On side of Ramp: The duplex outlet had been hit and crush by a vehicle, exposing energized parts, on or about 9/12/2016.
Recent events (2)
  • — I (S) $3802
  • — Z (S) $6338

1910.304 G05

Serious Gravity 5 3 instances 1 exposed
Issued
Mar 1, 2017
Abate by
Apr 14, 2017
Penalty
Initial $6,338 · Current $3,802 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    a) Building 18, Shop: The path to ground on the Skilsaw was not continuous, the equipment plug was missing it's ground pin, on or about 9/12/2016.    b) Building 18, Shop: Dayton Industrial pedestal fan, tag #09513CN, was missing a ground pin, on or about 9/12/2016.    c) Building 18, Shop: Dayton industrial pedestal fan, Tag # ??213CH, was missing a ground pin, on or about 9/12/2016.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (2)
  • — I (S) $3802
  • — Z (S) $6338

1910.305 A02 IX

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 1, 2017
Abate by
Apr 14, 2017
Penalty
Initial $6,338 · Current $3,802 Reduced
29 CFR 1910.305(a)(2)(ix): All lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lampholder with a guard.     a)   Building 18, Storage Area: Fluorescent lighting provided in the storage area was not provided with a guard, on or about 9/12/2016.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (2)
  • — I (S) $3802
  • — Z (S) $6338

1904.32 B04 III

Other-than-serious 1 instance 5 exposed
Issued
Mar 1, 2017
Abate by
Apr 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1904.32(b)(4)(iii): The highest ranking company official working at the establishment did not certify the OSHA Form 300A;     a) Harris Camden Terminal Equipment, located at 2201 Mt Ephraim Avenue, Building 18, Camden NJ:  The highest ranking company official did not certify the annual summary (OSHA Form 300A) for the 2013 calendar year, observed on or about 9/12/2016.       b) Harris Camden Terminal Equipment, located at 2201 Mt Ephraim Avenue, Building 18, Camden NJ:  The highest ranking company official did not certify the annual summary (OSHA Form 300A) for the 2014 calendar year, observed on or about 9/12/2016.     NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341765766.