Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HENKELS & MCCOY GROUP, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of HENKELS & MCCOY GROUP, INC. in SPECTRA ENERGY CORPORATION 480 BOW CREEK ROAD, GRANTVILLE, PA 17028 (NAICS 237120). OSHA activity number 341767747.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Henkels & Mccoy Group, INC. — free Get an email when a new federal OSHA severe-injury report for Henkels & Mccoy Group, INC. is published. One employer, no account, unsubscribe in one click.
Site address
SPECTRA ENERGY CORPORATION 480 BOW CREEK ROAD
City
GRANTVILLE
State
PA
ZIP
17028
Mailing
985 JOLLY ROAD, BLUE BELL, PA 19422
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237120
Employees
24
Ownership type
A

5 citations on file for this inspection.

1910.134 I05 III

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Mar 10, 2017
Abate by
Apr 5, 2017
Penalty
Initial $7,243 · Current $0 Reduced

Hazardous substances 05300560501090109130

29 CFR 1910.134(i)(5)(iii): The employer did not ensure that compressor(s) used to supply breathing air to respirators were constructed and situated so as to have had suitable in-line air-purifying sorbent beds and filters to further ensure breathing air quality:  (Construction Reference 1926.103)  a)  Station Road, Grantville, Pennsylvania - On or about September 13, 2016, the employer did not ensure that the Sullivan-Palatek 2008 Model # D0185 QH11JDB SN # 28670 [Site # 88435] diesel-powered oil-lubricated air compressor was equipped with suitable in-line air-purifying sorbent beds and filters to ensure breathing air quality.     Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
  • — F (S) $0
  • — C (S) $7243
  • — Z (S) $7243

1910.134 I05 IV

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Mar 10, 2017
Abate by
Apr 5, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 05300560501090109130

29 CFR 1910.134(i)(5)(iv): The employer did not ensure that compressor(s) used to supply breathing air to respirators had a tag, maintained at the compressor, indicating the most recent filter/sorbent bed change date and the signature of the person authorized by the employer to perform the change:  (Construction Reference 1926.103)  a)  Station Road, Grantville, Pennsylvania - On or about September 13, 2016, the employer did not ensure that the Sullivan-Palatek 2008 Model # D0185 QH11JDB SN # 28670 [Site # 88435] diesel-powered oil-lubricated air was provided with maintenance tags.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.134 C01 VI

Other-than-serious 1 instance 3 exposed
Issued
Mar 10, 2017
Abate by
Aug 24, 2017
Penalty
Initial $1,016 · Current $1,016

Hazardous substances 05300560501090109130

29 CFR 1910.134(c)(1)(vi): The written program did not contain procedures to ensure adequate air quality, quantity, and flow of breathing air for atmosphere-supplying respirators: (Construction Reference 1926.103)    a)  Station Road, Grantville, Pennsylvania - On or about September 13, 2016, the employer's written respiratory protection program did not contain specific information on how employees, exposed to 2-part pipe coating epoxy, condensed hydrocarbons, carbon monoxide, respirable particulates not otherwise regulated (PNOR), and respirable crystalline silica, would be assured of breathing at least Grade D quality breathing air.       Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
  • — F (O) $1016
  • — C (O) $1016
  • — Z (O) $1016

1910.134 C01 VII

Other-than-serious 1 instance 3 exposed
Issued
Mar 10, 2017
Abate by
Aug 24, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 05300560501090109130

29 CFR 1910.134(c)(1)(vii): The written program did not contain provisions for training of employees in the respiratory hazards to which they were potentially exposed during routine and emergency situations: (Construction Reference 1926.103)    a)  Station Road, Grantville, Pennsylvania - On or about September 13, 2016, the employer's written respiratory protection program did not contain specific provisions on training employees on respiratory hazards they were exposed to, such as but not limited to, 2-part pipe coating epoxy, carbon monoxide, respirable particulates not otherwise regulated (PNOR), and respirable crystalline silica.       Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.134 C01 IX

Other-than-serious 1 instance 3 exposed
Issued
Mar 10, 2017
Abate by
Apr 26, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 05300560501090109130

29 CFR 1910.134(c)(1)(ix): The written respiratory protection program did not contain procedures for regularly evaluating the effectiveness of the program: (Construction Reference 1926.103)  a)  Station Road, Grantville, Pennsylvania - On or about September 13, 2016, the employer's written respiratory protection program did not contain specific procedures on how the program would be evaluated.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.