EL PASO, TX —
OSHA Inspection: M & N PLASTICS
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of M & N PLASTICS in 7750 TRADE CENTER AVE., EL PASO, TX 79912 (NAICS 326121). OSHA activity number 341767812.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- M & N PLASTICS
- Site address
- 7750 TRADE CENTER AVE.
- City
- EL PASO
- State
- TX
- ZIP
- 79912
- Mailing
- 7750 TRADE CENTER AVE., EL PASO, TX 79912
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326121
- Employees
- 54
- Ownership type
- A
Citations
4 citations on file for this inspection.
1904.39 A02
- Issued
- Sep 30, 2016
- Penalty
- Initial $536 · Current $322 Reduced
General-duty citation text
29 CFR 1904.39(a)(2): The employer did not report an in-patient hospitalization, amputation, or loss of an eye as a result of a work-related incident to OSHA within twenty-four (24) hours: Production Area: On or about September 7, 2015 and at times prior thereto, the employer did not report the in-patient hospitalization of one of their employees within 24 hours.
Recent events (2)
- — I (O) $321.6
- — Z (O) $536
1910.304 B03 II C 3
- Issued
- Sep 30, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(b)(3)(ii)(C)(3): Each cord set, attachment cap, plug, and receptacle of cord sets, and any equipment connected by cord and plug were not visually inspected before use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage, and equipment found damaged or defective was not removed from use until repaired: Production area: On or about October 16, 2016 and at times prior thereto; an extension cord supplying power to equipment was missing the grounding prong. This condition exposed the employees to electrical shock hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.304 G05
- Issued
- Sep 30, 2016
- Penalty
- Initial $953 · Current $572 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: Production area: On or about September 16, 2016 and at times prior thereto; the employer did not ensure that ground the Maguire Mixer was continuous and effective.
Recent events (2)
- — I (O) $571.8
- — Z (O) $953
1910.305 G02 III
- Issued
- Sep 30, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: Production Area: On or about September 16, 2016 and at times prior thereto, the strain relief was damaged on the power strip. This condition exposed the employees to electrical shock hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at M & N Plastics
View M & N Plastics's full OSHA safety record →
More inspections in this industry (NAICS 326121)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341767812.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.