Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. DEPARTMENT OF INTERIOR

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of U.S. DEPARTMENT OF INTERIOR in PO BOX 168, YELLOWSTONE NATIONAL PARK, WY 82190 (NAICS 712190). OSHA activity number 341767846.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Department of Interior — free Get an email when a new federal OSHA severe-injury report for U.S. Department of Interior is published. One employer, no account, unsubscribe in one click.
Site address
PO BOX 168
City
YELLOWSTONE NATIONAL PARK
State
WY
ZIP
82190
Mailing
PO BOX 168, YELLOWSTONE NATIONAL PARK, WY 82190
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
712190
Employees
1000
Ownership type
D

5 citations on file for this inspection.

1910.110 F02 I

Serious Gravity 5 1 instance 5 exposed
Issued
Dec 7, 2016
Abate by
Jan 4, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.110(f)(2)(i): Containers in storage shall be located so as to minimize exposure to excessive temperature rise, physical damage, or tampering by unauthorized persons:  a) Wolf Management Storage Area: On or about August 2, 2016, and at times prior, employees were exposed to struck by and explosion hazards while working in and around an unsecured propane tank located near the sliding door. This is a high vehicle and foot traffic area.
Recent events (1)
  • — Z (S) $0

1910.134 H02 I

Serious Gravity 1 1 instance 5 exposed
Issued
Dec 7, 2016
Abate by
Jan 4, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or  were not packed or stored to prevent deformation of the face piece and exhalation valve:  a) Bear Management Office: On or about August 2, 2016, and at times prior, employees were exposed to respiratory hazards by improper storage of N95 dust masks on hooks in the office.
Recent events (1)
  • — Z (S) $0

1910.303 F02

Serious Gravity 5 1 instance 10 exposed
Issued
Dec 7, 2016
Abate by
Jan 4, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  a) Lake Fisheries garage: On or about August 2, 2016, and at times prior, employees were exposed to hazards associated with not being able to identify disconnections to de-energize the facility or equipment in the event of an emergency.
Recent events (1)
  • — Z (S) $0

1910.305 B02 I

Serious Gravity 5 2 instances 10 exposed
Issued
Dec 7, 2016
Abate by
Jan 4, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  a) Canyon Visitors Center basement hallway: On or about August 2, 2016, employees were exposed to electrical shock and fire hazards while walking and working near unguarded electrical wires due to broken or missing faceplates in basement area next to the gym.     a) Canyon Visitors Center boiler room: On or about August 2, 2016, and at times prior, employees were exposed to shock hazards while performing maintenance on and working near boiler 2 while the boiler control box was missing a faceplate had exposed electrical wiring.
Recent events (1)
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 5 3 instances 20 exposed
Issued
Dec 7, 2016
Abate by
Jan 4, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a) Canyon Visitors Center Regional Interpretive office: On or about August 2, 2016 and at times prior, employees were exposed to shock and fire hazards by use of a flexible extension cord as permanent wiring to energize a computer station.  b) Canyon Visitors Center sever room: On or about August 2, 2016 and at times prior, employees were exposed to shock and fire hazards by use of a flexible extension cord as permanent wiring to energize computer terminal servers.  c) Lake Fisheries area: On or about August 2, 2016 and at times prior, employees were exposed to shock and fire hazards by temporary wiring used as permanent wiring to energize the garage door opener on bay #3.
Recent events (1)
  • — Z (S) $0

View U.S. Department of Interior's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341767846.