Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: W. S. TUCKPOINTING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of W. S. TUCKPOINTING, INC. in 326 WESLEY AVE., OAK PARK, IL 60302 (NAICS 238140). OSHA activity number 341776094.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch W. S. Tuckpointing, INC. — free Get an email when a new federal OSHA severe-injury report for W. S. Tuckpointing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
326 WESLEY AVE.
City
OAK PARK
State
IL
ZIP
60302
Mailing
13754 MCCARTHY RD., LEMONT, IL 60439
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
4
Ownership type
A

4 citations on file for this inspection.

1926.451 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 20, 2016
Abate by
Nov 1, 2016
Penalty
Initial $3,741 · Current $2,244 Reduced
29 CFR 1926.451(b)(1):  Each platform on all working levels was not fully planked or decked between front uprights and the guardrail supports:       a) On September 15, 2016, employees working from frame scaffolding were exposed to fall hazards of greater than 25 feet where the scaffold platform was not fully decked.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2244
  • — Z (S) $3741

1926.451 G01

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 20, 2016
Abate by
Nov 1, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1):  Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level:    a)  On September 15, 2016, employees working from frame scaffolding were exposed to fall hazards of greater than 25 feet.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 E01

Serious Gravity 1 1 instance 3 exposed
Issued
Oct 20, 2016
Abate by
Nov 1, 2016
Penalty
Initial $1,604 · Current $1,012 Reduced
29 CFR 1926.451(e)(1):  Portable ladder, hook-on ladder, attachable ladder, stair tower, stairway-type ladder, ramp, runway, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used to access scaffold platforms more than 2 feet above or below a point of access:       a)  Employees were exposed to a fall hazard of approximately 7 feet while climbing walk-through scaffold frames.      In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1012
  • — Z (S) $1604

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 20, 2016
Abate by
Nov 1, 2016
Penalty
Initial $3,741 · Current $2,244 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):       a)  On September 15, 2016, employees performing masonry work were exposed to fall hazards of greater than 25 feet.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2244
  • — Z (S) $3741

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341776094.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.