QUITMAN, MS —
OSHA Inspection: HARDEES
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of HARDEES in 302 NORTH ARCHUSA AVE., QUITMAN, MS 39355 (NAICS 722211). OSHA activity number 341777506.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HARDEES
- Site address
- 302 NORTH ARCHUSA AVE.
- City
- QUITMAN
- State
- MS
- ZIP
- 39355
- Mailing
- 302 NORTH ARCHUSA AVE., QUITMAN, MS 39355
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 722211
- Employees
- 25
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.304 B03 I
- Issued
- Nov 9, 2016
- Abate by
- Nov 28, 2016
- Penalty
- Initial $1,817 · Current $1,090 Reduced
General-duty citation text
29 CFR 1910.304(b)(3)(i): All 125-volt, single-phase, 15- and 20-ampere receptacles installed in bathrooms or on rooftops did not have ground-fault circuit-interrupter protection for personnel. a. Food Prep - On or about September 15, 2016 the two receptacles next to the hand sink did not have ground-fault circuit interrupters to protect employees from electric shock.
Recent events (2)
- — I (S) $1090.2
- — Z (S) $1817
1910.305 B02 I
- Issued
- Nov 9, 2016
- Penalty
- Initial $1,545 · Current $927 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: a. Burger Makeup Table - On or about September 15, 2016 the junction box underneath the burger makeup table did not have a cover.
Recent events (2)
- — I (S) $927
- — Z (S) $1545
1910.305 G02 II
- Issued
- Nov 9, 2016
- Abate by
- Nov 28, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used in continuous lengths without splice or tap. a. Breakfast Grill - on or about September 15, 2016 the electrical power cord for the grill was spliced. An orange flexible cord was sliced into the grill electrical cord.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G02 III
- Issued
- Nov 9, 2016
- Abate by
- Nov 28, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws. a. Hardees - On or about September 15, 2016 the male plug for the breakfast grill and the Bunn coffee pot did not have strain relief. The conduit for the junction box underneath the burger prep table did not have strain relief.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Hardees
View Hardees's full OSHA safety record →
More inspections in this industry (NAICS 722211)
More inspections in MS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341777506.