Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ESTEX FABRIC FABRICATIONS, INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ESTEX FABRIC FABRICATIONS, INC in 402 BROAD STREET, FAIRBURN, GA 30213 (NAICS 314912). OSHA activity number 341784445.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Estex Fabric Fabrications, INC — free Get an email when a new federal OSHA severe-injury report for Estex Fabric Fabrications, INC is published. One employer, no account, unsubscribe in one click.
Site address
402 BROAD STREET
City
FAIRBURN
State
GA
ZIP
30213
Mailing
402 BROAD STREET, FAIRBURN, GA 30213
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
314912
Employees
100
Ownership type
A

2 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 21, 2016
Abate by
Jan 18, 2017
Penalty
Initial $7,482 · Current $4,489 Reduced
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle:  Main shop area. on or about August 30 2016 and at times prior, the employer exposed employees to a caught in hazard in that the Edward Segal Grommet Machine used a foot operated control switch instead of a two hand control that allowed employees hands into the point of operation.
Recent events (2)
  • — I (S) $4489.2
  • — Z (S) $7482

1910.305 G02 III

Other-than-serious 1 instance 3 exposed
Issued
Dec 21, 2016
Abate by
Jan 11, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  (a) Main shop area. on or about September 20, 2016 and at times prior the employer exposed employees to a heat hazard in that employees were operating a Eastman drill marker that had exposed wires coming into the top.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341784445.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.