EVANSTON, IL —
OSHA Inspection: GARCIA ROOFING EXTERIORS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GARCIA ROOFING EXTERIORS, INC. in 807 ROSLYN PLACE, EVANSTON, IL 60201 (NAICS 238160). OSHA activity number 341788750.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GARCIA ROOFING EXTERIORS, INC.
- Site address
- 807 ROSLYN PLACE
- City
- EVANSTON
- State
- IL
- ZIP
- 60201
- Mailing
- 6351 S. KNOX AVE., CHICAGO, IL 60629
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
7 citations on file for this inspection.
1903.19 C01
- Issued
- Dec 5, 2016
- Abate by
- Jan 9, 2017
- Penalty
- Initial $300 · Current $200 Reduced
General-duty citation text
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: Garcia Roofing Exteriors, Inc., failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected: Citation Number Item Number Abatement Date 01 01 09/29/2016 01 02a 09/29/2016 01 02b 09/29/2016 01 02c 09/29/2016 02 01 09/29/2016 03 01 09/29/2016 In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $200
- — Z (O) $300
1926.102 A01
- Issued
- Sep 23, 2016
- Abate by
- Sep 29, 2016
- Penalty
- Initial $2,352 · Current $2,352
General-duty citation text
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection when machines or operations present potential eye or face injury from physical, chemical, or radiation agents: a) On or about September 22, 2016, employees were exposed to eye injury while operating pneumatic nail guns and electric circular saws without the benefit of eye protection. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
- — F (S) $2352
- — C (S) $2352
- — Z (S) $2352
1926.451 G01 III
- Issued
- Sep 23, 2016
- Abate by
- Sep 29, 2016
- Penalty
- Initial $4,115 · Current $4,115
General-duty citation text
29 CFR 1926.451(g)(1)(iii): Each employee on a crawling board (chicken ladder) was not protected by a personal fall arrest system, a guardrail system (with minimum 200 pound toprail capacity), or by a three-fourth inch (1.9 cm) diameter grabline or equivalent handhold securely fastened beside each crawling board: a) On or about September 23, 2016, employees were exposed to the hazard of falling from a pitched roof while on a crawling board (chicken ladder) located on the roof of a two story building. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — F (S) $4115
- — C (S) $4115
- — Z (S) $4115
1926.452 M01
- Issued
- Sep 23, 2016
- Abate by
- Sep 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(m)(1): Crawling boards did not extend from the roof peak to the eaves when used in connection with roof construction, repair, or maintenance: a) On or about September 22, 2016, ladders used as crawling boards ("chicken" ladders) did not extend from the roof peak to the eave when used during roofing work. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.452 M02
- Issued
- Sep 23, 2016
- Abate by
- Sep 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(m)(2): Crawling boards were not secured to the roof by ridge hooks or by means that meet equivalent criteria (e.g., strength and durability): a) On or about September 22, 2016, ladders used as crawling boards ("chicken ladders") were not secured to the roof by ridge hooks or by other means. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Sep 23, 2016
- Abate by
- Sep 29, 2016
- Penalty
- Initial $8,231 · Current $8,231
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a) On or about September 22, 2016, employees were exposed to the hazard of falling while working from the roof of a two story residential structure without fall protection. Esteban Garcia dba Garcia Roofing Exteriors, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13) which was contained in OSHA inspection number 1018656, citation 1, item 2b, and was affirmed as a final order on June 4, 2016, with respect to a worksite located at 2300 Ash Lane, Northbrook, Illinois. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — F (R) $8231
- — C (R) $8231
- — Z (R) $8231
1926.502 D15
- Issued
- Sep 23, 2016
- Abate by
- Sep 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person: a) On or about September 22, 2016, a ridge anchor used as part of a fall protection system was not connected completely to the ridge to ensure the device would be capable of supporting at least 5,000 pounds of force. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at Garcia Roofing Exteriors, INC.
View Garcia Roofing Exteriors, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in IL
Source