Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ALDRICH CLEAN-TECH EQUIPMENT

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ALDRICH CLEAN-TECH EQUIPMENT in 84 WASHINGTON STREET, WOBURN, MA 01801 (NAICS 423850). OSHA activity number 341794741.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Aldrich Clean-Tech Equipment — free Get an email when a new federal OSHA severe-injury report for Aldrich Clean-Tech Equipment is published. One employer, no account, unsubscribe in one click.
Site address
84 WASHINGTON STREET
City
WOBURN
State
MA
ZIP
01801
Mailing
59 WEBSTER PLACE, WORCESTER, MA 01603
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423850
Employees
12
Ownership type
A

3 citations on file for this inspection.

1910.132 A

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 14, 2017
Penalty
Initial $5,070 · Current $2,525 Reduced
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered.    (a) Location: 84 Washington, Woburn, MA 01801.  On or about September 23, 2016, an employee was working/walking on a roof and collapsed within four feet of a roof's edge at a height greater than 20 feet above lower level were no fall protection system was in place.
Recent events (2)
  • — I (S) $2525
  • — Z (S) $5070

1910.333 B02

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 14, 2017
Penalty
Initial $5,070 · Current $2,525 Reduced
29 CFR 1910.333(b)(2): While an employee was exposed to contact with parts of fixed electric equipment or circuits which were deenergized, the circuits energizing the parts were not locked out or tagged or both in accordance with the requirements of this paragraph (b) of 29 CFR 1910.333(b)(2):    (a) Location; 84 Washington Street, Woburn, MA   On or about September 23, 2016 an employee was exposed to electrical shock and burns because he did not lock or tag out de-energized electrical circuit.
Recent events (2)
  • — I (S) $2525
  • — Z (S) $5070

1910.333 B02 IV

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.333(b)(2)(iv): Verification of deenergized condition. The requirements of this paragraph shall be met before any circuits or equipment can be considered and worked as deenergized.  (a) location: 34 Washington Street, Woburn, MA 01801. On or about September 23, 2016, an employee was removing and replacing an electrical water pump were no electrical tester that he or the company owned was present to verify the absence of voltage.