Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JOSE LUIS GARCIA

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JOSE LUIS GARCIA in 105 N. 9TH STREET, MCALLEN, TX 78501 (NAICS 238140). OSHA activity number 341796373.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Jose Luis Garcia — free Get an email when a new federal OSHA severe-injury report for Jose Luis Garcia is published. One employer, no account, unsubscribe in one click.
Establishment
JOSE LUIS GARCIA
Site address
105 N. 9TH STREET
City
MCALLEN
State
TX
ZIP
78501
Mailing
105 N. 9TH STREET, MCALLEN, TX 78501
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.451 B01

Serious Gravity 10 1 instance 4 exposed
Issued
Mar 10, 2017
Penalty
Initial $3,803 · Current $2,100 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii):    At a commercial construction site, employees were installing foam panels to the exterior walls of a commercial building under construction on incomplete platforms of tubular frame scaffolds.  The working platforms were not fully planked; exposing employees to fall hazards.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3803

1926.451 C02

Serious Gravity 10 1 instance 4 exposed
Issued
Mar 10, 2017
Penalty
Initial $3,803 · Current $2,100 Reduced
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates, mud sills or other adequate firm foundation:    At a commercial construction site, employees used a tubular frame scaffold without base plates.  Employees were exposed to fall hazards 10 feet above ground.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3803

1926.451 E01

Serious Gravity 10 1 instance 4 exposed
Issued
Mar 10, 2017
Penalty
Initial $3,803 · Current $2,100 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Cross braces were used as a means of access.    At a commercial construction site, a tubular frame scaffold located throughout a commercial building under construction and used by employees, did not have a ladder or other safe means to gain access to the scaffold platforms.  Employees were exposed to falls 10 feet above ground.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3803

1926.451 F06

Serious Gravity 10 1 instance 4 exposed
Issued
Mar 10, 2017
Abate by
Mar 22, 2017
Penalty
Initial $3,803 · Current $2,100 Reduced
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).Note:  Specify distances as indicated in table in paragraph (f)(6) of this section.    At a commercial construction site, employees were exposed to electrical hazards while using a tubular frame scaffold to install foam panels to the exterior walls of a commercial building under construction,1 1/2 feet from an overhead electrical power line.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3803

1926.451 G01 VII

Serious Gravity 10 1 instance 4 exposed
Issued
Mar 10, 2017
Penalty
Initial $3,803 · Current $2,100 Reduced
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section:    At a commercial constructions site, employees used a tubular frame scaffold without fall protection, while installing foam panels to the exterior walls of a commercial building under construction.  Employees were exposed to fall hazards of more than 10 feet.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3803

View Jose Luis Garcia's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341796373.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.