OSHA Inspection: CUSTOM PLASTICS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CUSTOM PLASTICS, INC. in 1940 LUNT AVE., ELK GROVE VILLAGE, IL 60007 (NAICS 326199). OSHA activity number 341797272.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Custom Plastics, INC. — free Get an email when a new federal OSHA severe-injury report for Custom Plastics, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1940 LUNT AVE.
City
ELK GROVE VILLAGE
State
IL
ZIP
60007
Mailing
1940 LUNT AVE., ELK GROVE VILLAGE, IL 60007
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
160
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 9, 2017
Abate by
Apr 4, 2017
Penalty
Initial $11,408 · Current $11,408
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in the activities covered by this section:   a) Extruder Area - On or about September 22, 2016, the employer did not ensure equipment-specific energy control procedures were utilized for the control of potentially hazardous energy when an employee was conducting servicing and maintenance by unjamming a strip of plastic during the operation of the RDN Manufacturing Co. Inc., Intellicut model #C420A, serial #42027. This machine had electrical and pneumatic energy.
Recent events (2)
  • — I (S) $11408
  • — Z (S) $11408

1910.147 C04 II

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 9, 2017
Abate by
Apr 4, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to items (a) through (d) of this section:   a) Extruder Area - On or about September 22, 2016, the employer did not ensure that there was an equipment-specific energy control procedure for the task of unjamming material from the RDN Manufacturing Co. Inc., Intellicut model #C420A, serial #42027, that included the following items: a specific statement of the intended use of the procedure (servicing, maintenance, and/or un-jamming), procedural steps for shutting down, isolating and securing the machine to control hazardous energy (electrical and pneumatic), procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them, and specific requirements for testing the machine to determine and verify the effectiveness of the lockout devices, tagout devices and other energy control measures.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 9, 2017
Abate by
Apr 4, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  a) Extruder Area - On or about September 22, 2016, an employee was exposed to machine hazards associated with moving parts and struck-by hazards while unjamming a plastic strip on the RDN Manufacturing Co. Inc., Intellicut model #C420A, serial #42027.  The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements].  As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)], and verification of isolation [(d)(6)], were not implemented to protect the employee from machine servicing hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 9, 2017
Abate by
Apr 4, 2017
Penalty
Initial $11,408 · Current $0 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices:    a) Extruder Area - On or about September 22, 2016, the employer did not ensure an employee that unjammed a plastic strip on the RDN Manufacturing Co. Inc., Intellicut model #C420A, serial #42027, was trained as an Authorized employee.  The employee performed this servicing and maintenance task without the knowledge and skills needed for the safe application, usage, and removal of the energy controls.  This machine had electrical and pneumatic energy.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11408

View Custom Plastics, INC.'s full OSHA safety record →