THORNTON, CO —
OSHA Inspection: NEXT GENERATION CONSTRUCTION AND ENVIRONMENTAL, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of NEXT GENERATION CONSTRUCTION AND ENVIRONMENTAL, LLC in 13651 SYRACUSE, THORNTON, CO 80023 (NAICS 238910). OSHA activity number 341800449.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NEXT GENERATION CONSTRUCTION AND ENVIRONMENTAL, LLC
- Site address
- 13651 SYRACUSE
- City
- THORNTON
- State
- CO
- ZIP
- 80023
- Mailing
- 14313 MEAD STREET, LONGMONT, CO 80504
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.651 K01
- Issued
- Oct 17, 2016
- Abate by
- Nov 21, 2016
- Penalty
- Initial $6,236 · Current $4,365 Reduced
General-duty citation text
29 CFR 1926.651(k)(1): An inspection of the excavations, the adjacent areas, and protective systems was not conducted by a "competent person" prior to the start of work and as needed throughout the shift: (a) Next Generation Construction and Environmental, LLC, 13651 Syracuse, Thornton, CO: On or about September 26, 2016, the employer did not ensure a "competent person" conducted an inspection of the 12 foot deep vertical wall excavation to ensure an appropriate protective system was installed prior to entry. An employee entered the unprotected excavation to locate an existing 4 inch plastic sewer line. This condition exposed the employee to crushing hazards associated with cave-in hazards.
Recent events (2)
- — I (S) $4365
- — Z (S) $6236
1926.652 A01
- Issued
- Oct 17, 2016
- Abate by
- Oct 31, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(b) or (c): (a) Next Generation Construction and Environmental, LLC, 13651 Syracuse, Thornton, CO: On or about September 26th, 2016, the employer did not ensure an employee who entered an excavation for the purpose of locating an existing 4 inch plastic sewer pipe was protected from cave-in hazards. The 12 foot deep excavation with a vertical wall excavation was not sloped, shored, sheeted, and no trench box was in use. This condition exposed the employee to crushing hazards associated with cave-in hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238910)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341800449.