Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TRIPLE M MACHINE

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of TRIPLE M MACHINE in 231 COUNTY ROAD 452, ORLA, TX 79770 (NAICS 213112). OSHA activity number 341803674.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Triple M Machine — free Get an email when a new federal OSHA severe-injury report for Triple M Machine is published. One employer, no account, unsubscribe in one click.
Establishment
TRIPLE M MACHINE
Site address
231 COUNTY ROAD 452
City
ORLA
State
TX
ZIP
79770
Mailing
3211 W. MURPHY ST., ODESSA, TX 79763
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
10
Ownership type
A

2 citations on file for this inspection.

1910.147 D05 I

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 2, 2017
Abate by
Feb 24, 2017
Penalty
Initial $3,803 · Current $3,803
29 CFR 1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices:     Amine Unit:  On or about September 26, 2016 all potentially hazardous energy was not relieved on pump P-0116A after the application of lockout tagout devices.   This condition exposed employees to a burn hazard.
Recent events (2)
  • — I (S) $3803
  • — Z (S) $3803

1910.147 D06

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 2, 2017
Abate by
Feb 24, 2017
Penalty
Initial $3,803 · Current $0 Reduced
29 CFR 1910.147(d)(6): Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and deenergization of the machine or equipment had been accomplished:    Amine Unit:  On or about September 26, 2016 prior to starting maintenance on P-0116S the authorized employee did not verify that all potentially hazardous energy was not relieved on pump P-0116A after the application of lockout tagout devices.   This condition exposed employees to a burn hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3803

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341803674.