Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: STATION REMOVAL AND INSTALLATION, LLC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of STATION REMOVAL AND INSTALLATION, LLC. in 1237 PARK STREET, PALMER, MA 01069 (NAICS 238910). OSHA activity number 341806263.

Watch Station Removal AND Installation, LLC. — free Get an email when a new federal OSHA severe-injury report for Station Removal AND Installation, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
1237 PARK STREET
City
PALMER
State
MA
ZIP
01069
Mailing
19 RICH STREET, EVERETT, MA 02149
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
4
Ownership type
A

5 citations on file for this inspection.

1903.19 C01

Other-than-serious 3 instances 2 exposed
Issued
Abate by
Penalty
Initial $305.00 · Current $305.00
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:  As of February 27, 2017, the employer had not certified abatement was completed for violations Citation 1 Item 1a, Citation 1 Item 1b and Citation 2 Item 1, from inspection 1187994, issued November 21, 2016 with a final order date of December 22, 2016, and an abatement date of December 16, 2016.
Recent events (1)
  • — Z (O) $305

1903.19 D01

Other-than-serious 3 instances 2 exposed
Issued
Abate by
Penalty
Initial $305.00 · Current $305.00
29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required.  As of February 27, 2017, the employer had not submitted documents to the agency demonstrating abatement was completed for violations Citation 1 Item 1a, Citation 1 Item 1b and Citation 2 Item 1, from inspection 1187994, issued November 21, 2016 with a final order date of December 22, 2016 and an abatement date of December 16, 2016.
Recent events (1)
  • — Z (O) $305

1910.134 C

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3741.00 · Current $3741.00
29 CFR 1910.134(c)(1): The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use: (Construction Reference 1926.103)  12372 Park Street, Palmer, MA: On or about September 29, 2016 employees were required to wear SCBA respirators in the execution of their work duties and the employer had not developed and implemented a written respiratory protection plan with work site specific procedures and elements for the required respirator use.   Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (1)
  • — Z (S) $3741

1910.134 F02

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting face piece respirator were not annually fit tested: (Construction Reference 1926.103  12372 Park Street, Palmer, MA: On or about September 29, 2016 employees were required to wear tight fitting respirators in the execution of their work duties and the employer had not ensured such employees were fit tested prior to their use.  Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (1)
  • — Z (S) $0

1926.1203 D

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3741.00 · Current $3741.00
29 CFR 1926.1203(d)(1): The employer had employees it directs enter a permit space and did not have a written permit space program that complies with �1926.1204 at the construction site.   1237 Park Street, Palmer, MA: On or about September 29, 2016 employees were required to enter permit required confined spaces in the form of single walled steel, underground gasoline fuel storage tanks which had been recently excavated in order to replace them with new double walled steel tanks.  Employees were required to enter these excavated tanks in order to clean and sanitize them of remaining hydrocarbons and petroleum distillates in preparation for disposal.   During this operation a written program that complies to 1926.1204 was not available prior to or during entry operations for inspection by affected employees and their representatives.  Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (1)
  • — Z (S) $3741

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341806263.