Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GEAUGA MECHANICAL

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of GEAUGA MECHANICAL in 12585 CHARDON-WINDSOR RD, CHARDON, OH 44024 (NAICS 541330). OSHA activity number 341808889.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Geauga Mechanical — free Get an email when a new federal OSHA severe-injury report for Geauga Mechanical is published. One employer, no account, unsubscribe in one click.
Establishment
GEAUGA MECHANICAL
Site address
12585 CHARDON-WINDSOR RD
City
CHARDON
State
OH
ZIP
44024
Mailing
12585 CHARDON-WINDSOR RD, CHARDON, OH 44024
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541330
Employees
58
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 4 exposed
Issued
Oct 20, 2016
Penalty
Initial $8,730 · Current $5,218 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    On or about September 19, 2016, the employer failed to ensure that machine specific procedures for the control of hazardous energies were in place for equipment within the facility. Employees are tasked with servicing, maintaining, or setting up equipment such as but not limited to press brakes, shears, benders, and gorelockers. Hazardous energies include but are not limited to mechanical, electrical, pneumatic, gravitational, and hydraulic.
Recent events (2)
  • — I (S) $5218
  • — Z (S) $8730

1910.147 C06 I

Serious Gravity 10 3 instances 4 exposed
Issued
Oct 20, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  On or about September 19, 2016, the employer had not performed a periodic inspection of the energy control procedures within the last year in which maintenance, servicing, or set up of equipment had taken place. The company had in place a written LO/TO program, however machine specific procedures were not in place.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 10 3 instances 4 exposed
Issued
Oct 20, 2016
Penalty
Initial $8,730 · Current $5,218 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a) On or about September 19, 2016, the employer failed to ensure that the Roto-Die press brake was effectively guarded to prevent employee contact with the hazardous area of the dies closing. Barrier guards and other devices were not in place on both the front and rear of the equipment. The mechanical action of the press brake is controlled by foot pedal allowing the operator's hands to reach the hazard area.           b) On or about September 19, 2016, the employer failed to ensure that the Drossbach SGB 1250 Gorelocker was effectively guarded to prevent employees from contacting the pinch points of the rollers. The rotation of the rollers is controlled by foot pedal allowing the employee's hands to reach the hazard area during operation.        c) On or about September 19, 2016, the employer failed to ensure that the LockFormer Transverse Duct Connector was effectively guarded to prevent employees from the pinch points of the rollers. The barrier guard was not in place on the equipment while employees operated it.
Recent events (2)
  • — I (S) $5218
  • — Z (S) $8730

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341808889.